background image

en-3

Replace Light Bulb

Replace light bulb (1) with a 21 watt maximum light bulb. Insert bulb into socket as
shown. The light will turn on and remain lit for 2 1/2 minutes when power is
connected. After 2 1/2 minutes it will turn off.

21

Test the Safety Reverse System

The safety reverse system test is important. Garage door must reverse on
contact with a 40mm obstacle laid flat on the floor. Failure to properly adjust
opener may result in serious personal injury from a closing garage door.
Repeat test once a month and adjust as needed.

Procedure: 

Place a 40mm obstacle (1) laid flat on the floor under the garage door.

Operate the door in the 

down 

direction. The door 

must 

reverse on the obstruction.

If the door 

stops

on the obstruction, it is not traveling far enough in the 

down

direction. Move Close Limit closer to door.
When the door reverses on the 40mm obstacle, remove the obstruction and run the
opener through a complete travel cycle. Door 

must not

reverse in closed position. If

it does, adjust Limit and repeat safety reverse test.

Place 20kg at the center of the door and ensure that the door will not move up more
than 500mm.

SAVE THESE INSTRUCTIONS

19

Program Remotes

Activate the opener only when door is in full view, free of obstruction and
properly adjusted. No one should enter or leave garage while door is in
motion.

Your garage door opener receiver and Remote Control Transmitter are set to a
matching code. If you purchase additional Remote Controls, the garage door opener
must be programmed to accept the new Remote code.

To program receiver to match additional Remote Control codes:

1. Press and release the program button on the side of the unit (1). The green LED

will glow steadily for 30 seconds.

2. Within 30 seconds press and hold the button on the hand-held Remote (2).

3. Release the button when the motor unit light blinks. It has learned the code. If the

light bulb is not installed, two clicks will be hear.

To erase all codes from motor unit memory or to deactivate any unwanted
Remote, first erase all codes:

Press and hold the program button (1) on motor unit until the learn indicator light
goes out (approximately 6 seconds). All previous codes are now erased. Reprogram
each Remote or Keyless Entry you wish to use.

20

Operation Of Your Opener

Your opener can be activated by any of the following devices:

• The Remote Control Transmitter. Hold the push button down until the door starts to

move.

• The Lighted Door Control Button (if you have installed this accessory). Hold the

button down until door starts to move.

• The Outside Keylock or Keyless Entry System (if you have installed either of these

accessories). 

Opening the Door Manually:

Door should be fully closed if possible. Weak or broken springs could allow an open
door to fall rapidly. 

Property damage or serious personal injury could result.

The door can be opened manually by pulling the release handle down. To reconnect
the door, activate the unit.

Do not use the manual release handle to pull the door open
or closed.

When the Opener is Activated by Remote Control or Door Control Button:

1. If fully open, the door will close.

2. If closed, the door will open. 

3. If opening or closing, the door will stop.

4. If partially open, the door will move in the opposite direction of last travel. 

5. If an obstruction is encountered while closing, the door will reverse to the open

position.

6. If an obstruction is encountered while opening, the door will reverse for 1 second. 

7. The optional Protector System™ uses an invisible beam which, when broken by

an obstruction, causes a closing door to open and prevents an open door from
closing. It is STRONGLY RECOMMENDED for homeowners with young children.

Allow a 15 minute cooling period after 5 continuous operations of the opener.

The opener light will turn on:  1. when opener is initially plugged in;
2. when the power is interrupted; 3. when the opener is activated. 

The light turns off automatically after 2-1/2 minutes. Bulb size is 
21 Watts maximum.

Setting the Force

The Force is programmed to operate most doors, however, if Limits are not able to
be set, or the door reverses during normal operation follow this procedure: Locate
the Program Button (1) on the left side panel of unit (2). Push the Program Button
twice to enter unit into Auto-Force Adjustment Mode. The green LED will flash
slowly. Activate unit with remote and run the unit to the Open Limit. Activate unit
again to run the unit to the Closed Limit. The door must travel through a complete
cycle up and down in order for the Force to be set properly. If the unit stops before it
reaches the Open or Close Limit repeat the process. The green LED will stop
flashing when the Force has been learned.

18

Attach Limit Switches

NOTE:

The limits must be installed as shown. If installed incorrectly the unit will not

function properly.

Close garage door by hand. Determine the position of the Close Limit Switch (1)
(Long wire) by aligning the center of trolley and the center of the Limit Switch. The
Limit Switches are actuated by a magnet in the Inner Trolley. Insert bottom tab (5) of
Limit Switch (1) into bottom lip of Rail (7). Insert top tab (4) under top lip of Rail (6).
Lift limit assembly against top lip of Rail and tighten screw (8) to secure Close Limit
Switch. Open garage door by hand to the full open position. Pull red handle to open
door past Inner Trolley. Determine the position of the Open Limit Switch (3) (Short
Wire) by aligning the center of the Trolley and the center of the Limit Switch. Insert
bottom tab (5) of Limit Switch (1) into bottom lip of rail (7). Insert top tab (4) under
top lip of rail (6). Lift limit assembly against top lip of rail and tighten screw (8) to
secure Open Limit Switch. Insert wires for Limit Switch (9) into top channel of Rail
(10). Secure wires with wire clip. the wires must be secured so they do not interfere
with the travel of the Trolley. Activate remote, the opener will operate and reconnect
to the door automatically. Run opener 2 full travel cycles. If the door reverses in mid
travel go to Setting the Force Section. Adjust Limit Switches as necessary to fully
open and close the door without reversing.

17

Summary of Contents for GPD60

Page 1: ...g 10m2 80kg Max m2 kg GPD60 GPD65 Instructions Garage Door Operator Model GPD60 GPD65 Instrucciones Abridor de la puerta de garaje Modelo GPD60 GPD65 Istruzioni Apriporta per garage Modello GPD60 GPD6...

Page 2: ...sted No one should enter or leave the garage while the door is in motion Do not allow children to play near the door Use manual release only to disengage the trolley and if possible ONLY when the door...

Page 3: ...Outer Trolley 1 into Rail assembly 2 be sure the end with Door Arm Hole 3 is heading in direction of door 4 Slide Outer Trolley down Rail until it engages with Inner Trolley Attach Rail to Unit Turn R...

Page 4: ...elease handle to pull the door open or closed When the Opener is Activated by Remote Control or Door Control Button 1 If fully open the door will close 2 If closed the door will open 3 If opening or c...

Page 5: ...he metal garage door foil backed insulation or metal siding will reduce the transmission range 3 Door reverses for no apparent reason and opener lights don t blink Is something obstruction the door Pu...

Page 6: ...rvice door and out of reach of children Run the bell wire up the wall and across the ceiling to the garage door opener Use insulated staples 5 to secure wire The opener Quick Connect Terminals 7 are l...

Page 7: ......

Page 8: ......

Page 9: ...114A3909 2009 Chamberlain GmbH All rights reserved...

Page 10: ...de ouvre porte de garage Illustrations Garage Door Operator Models GPD60 GPD65 Ilustraciones Abridor de la puerta de garage Modelo GPD60 GPD65 Illustrazioni Apriporta per garage Modelli GPD60 GPD65 Af...

Page 11: ...IGHT GPD65 GPD60 7 22 1 3 5 4 6 7 012B0905 012B0906 012C0908 012C0788 001B0911 GPD65 8 05765 2 9 183D0181 3 001A6355 3 4 piece rail GPD65 001A5643 6 10 11 12 001A4166 001B4494 1 L GPD60 4x GPD65 6x GP...

Reviews: