Operational Description TST WS-B
Page: 12
Wsb_bse8.doc
mt 041102
FEIG ELECTRONIC GmbH
8 Technical
data
Housing dimensions (W X H X D):
approx.: 182 x 320 x 93 mm (without mushroom-type button)
Printed circuit board dimensions
(L x W x H):
approx.: 210 x 170 x 70 mm (without plug-in module)
Mounting:
standing vertically
Supply:
Control device via L3, N, PE:
230 V
AC
±10%, 50...60 Hz
(Protected on the printed circuit board: F200/0.5AT)
Drive via L1, L2, L3:
up to 3x 400 V
AC
±10%, 50... 60 Hz, 2200 W at AC-3
(protection on site: 16 A, actuation
feature K)
additional motor protection (eg. thermoplate) required
Power cons. of the control device
approx. 30 VA (without drive and ext. 230 V consumer)
External power supply 1 (230 V):
230 V
AC
±10%, 50...60 Hz
(protected on the printed circuit board: F300/1 AT)
Control voltage/
external power supply
(external power supply 2):
•24 V
DC
irregularly
(±20% at nominal load of 200 mA and nominal voltage 230 V)
• max. 200 mA incl. all plug-in modules
• protected by self resetting semiconductor fuse
Control inputs:
• 24 VDC/typ. 15 mA
• all inputs are to be connected in a potential free manner or;
• <2V: inactive->logic 0
• > 17 V: active->logic 1
• min. signal duration of input control commands: >
100ms
• dc-insulated by optocoupler on the printed circuit board
Security chain/ emergency switch-off
incl. upper and lower end switches
• all inputs
must
be connected in a potential-free manner
• loadability of contact
≥
35VDC /
≥
200mA
• if the security chain is interrupted the drive can no longer move,
not even in deadman operation
• not bridged ex works
Relay outputs
• if inductive loads are connected (eg further relays), they must be provided
with free-wheeling diodes and appropriate fault clearing measures
Relay K1:
"warning light/red light”:
->230 VAC / min. 0.1 A / max. 80W
• L1 switching, closing device
Relay K2:
"fault/yard light":
->24 VDC/500 mA
->230 VAC/min. 0.1 A/ max. 80W
• switching in a potential free
manner, change-over contact
contacts used one time for a switch of
power current can not be uses anymore
for low currents
Auxiliary contacts on contactor
"opening travel" and "closing travel":
->230 VAC
• switching in a potential free manner, closing device
• fixedly coupled to motor opening travel or closing travel
Drive output
electromechanical brake
• 3x 400VAC, max. 2.2kW at AC-3
• connection directly to reversing contactor
• reversing contactor is prepared for operation of 3-phase drives
• 230 V
AC
actuation via contactor contacts (switched motor phase on
contactor, N+PE on clamping block)
• potential-free actuation via auxiliary contacts opening/closing travel
possible (eg DC braking)
Temperature range Operation:
Storage:
Air moisture
Vibration
Type of protection
Weight
-10...+50°C
-20...+70°C
up to 95% not condensing
low-vibration mounting, eg on a masonry wall
IP54 (IP65 by exchanging CEE connection and PG screw connection)
approx. 2.8kg
Directives
Standards:
EMV-directive:
89/336/EWG
Changed by:
91/263/EWG
92/031/EWG
EN 50081-1 / 03.93:
interferences, residential buildings
EN 50081-2 / 03.94:
interferences, industrial sector
EN 50082-2 / 02.96:
resistance to jamming, industrial sector
Low voltage directive:
73/023/EWG
changed by:
93/068/EWG
EN 60335-1 / 10.95:
safety of electric appliances for domestic use
and similar purposes / part 1: General
requirements
National technical specifications to be applied for
the above mentioned directives
prEN12453 / 09.99:
Gates – operating safety of power-operated
gates – requirements
prEN12978 / 11.99:
Gates – safety devices – requirements and
test methods