25
MODELS CSL24U AND CSW24U
SYMPTOM: Operator does not have power.
POWER
+
-
- -
BRIDGE
RECTIFIER
Orange
Black
Red
Black
Red
Orange
Power Wiring Connector
Power Wiring
Sockets
(120 Vac factory
default)
EMI
BOARD
(Back of Outlet Housing)
Input Power Connection
TRANSFORMER
Battery
12V 7AH
Battery
12V 7AH
Gray
Blue
Brown
Purple
Black
White
HOT
NEUTRAL
GROUND
Black
White
Green
OUTLET HOUSING
CONTROL BOARD
J15 Plug
1
2
3
4
5
6
Check the
incoming power.*
Check breaker first, then
check wiring coming
into operator.
The voltage should be
120 Vac or 240 Vac depending
on the application.
Check the AC power switch.
Is it ON?
Check the power
wiring connector.
Is it plugged into the correct
socket?
Check the transformer.*
Check the transformer voltage going into
the bridge rectifier (orange wires).
The reading should be 24 Vac (+/- 15%).
If not, replace the transformer.
Check the bridge
rectifier.*
Check the voltage coming
out of the bridge rectifer
(red and black wires).The
reading should be 35 Vdc
(+/- 15%).
If not, replace the bridge
rectifier.
7
Check the control
board.
Try replacing the fuse on
the control board. If that
does not work, replace
the control board.
Check the batteries.*
Check the battery connections. Make
sure two 7AH batteries OR two 33AH
batteries are connected in series.
Check the voltage coming from each
battery by disconnecting the battery
from the operator. A fully charged
battery should read 12.8 to 13.3 Vdc per
battery. If not, replace the batteries.
*
OUTLET HOUSING
DIAGNOSTICS
Fuse
CONTROL BOARD
TRANSFORMER and BRIDGE RECTIFIER
located on chassis, behind the electrical box.
BATTERIES
MODEL CSL24U
MODEL CSW24U
BATTERIES
OUTLET HOUSING
CONTROL BOARD
TRANSFORMER and BRIDGE RECTIFIER
located on chassis, behind the electrical box.
120
120
240
240