2
GARAGE DOOR
Secondary protection ONLY
Primary Monitored Entrapment
18" (46 cm) min.
48" (122 cm) min.
R
S
S
R
R
S
S
R
R
S
S
R
DOOR #1
DOOR #2
DOOR #3
R
= Receiving Sensor
S
= Sending Sensor
24" (61 cm) min.
Secondary protection ONLY
Primary Monitored Entrapment
Secondary protection ONLY
Primary Monitored Entrapment
Secondary protection ONLY
Primary Monitored Entrapment
R
S
S
R
6" (15 cm) max. above the
floor and away from the door
6" (15 cm) max. above the
floor and away from the door
6" (15 cm) max. above the
floor and away from the door
Wing
Nut
Mounting Bracket
Mounting
Bracket
6" (15 cm)
Max. above
the floor and away
from the door.
INSTALLATION
1. Attach the mounting brackets to a solid surface on each side of the door with hardware (provided) no more than 6" (15 cm) above the fl oor.
NOTE:
Track mount is not recommended.
2. Loosen the wing nut and slide the mounting bracket to adjust the photoelectric sensor.
SECONDARY PROTECTION AND ADJACENT DOOR INSTALLATIONS
Recommended installation for adjacent doors and more than one set of photoelectric sensors.
NOTE:
Secondary protection requires a CPS3 card.
Recommendations for optimizing operation of high volume vehicle traffi c with two sets of monitored photoelectric sensors.