Connections Overview
The CAPXS has a combination of access control inputs/outputs that work in conjunction to control one access point.
INPUT/OUTPUT
USED FOR
Postal Lock Input
External post lock input.
Wiegand Input
Standard 26-bit, 30-bit Wiegand, HID 37-bit with Facility Code, Transcore 37-bit, 32-bit MiFare.
Request to Exit & Supervised
Input
REX: Used to request activation/release of door for exit purposes. SUP: Used to monitor door/gate
closed state.
Primary Relay Output
Primary relay for door/gate release.
Auxiliary Relay Output
Auxiliary relay for door/gate release.
NOTE:
Only the 26-bit Wiegand protocol is compatible in UL installations.
PRIMARY RELAY - TERMINAL 9,10,11
POSTAL LOCK - TERMINAL 1,2
16 VDC
(+) Red
GROUND
AUXILIARY RELAY TERMINAL 12,13,14
WIEGAND INPUT - TERMINAL 3,4,5
REQUEST TO EXIT (REX) & SUPERVISED INPUT (SUP) - TERMINAL 6,7,8
ETHERNET
(–) Black
See pages 15-16 for wiring diagrams.