![Chamberlain BMT 5011U User Manual Download Page 3](http://html1.mh-extra.com/html/chamberlain/bmt-5011u/bmt-5011u_user-manual_2587095003.webp)
3
Photoelectric Sensor
ALTERNATE INSTALLATION: C2 WIRING TYPE WITH MONITORED
ENTRAPMENT PROTECTION DEVICE
• Momentary contact to open and stop with constant pressure to
close.
• Open override that reverses when closing by any opening
device.
• Wiring for entrapment protection device to reverse.
NOTE:
The operator will automatically convert to B2 wiring
when Monitored Entrapment Protection Device is installed. (See
accessories page for Monitored Entrapment ProtectionDevices.)
• Timer-to-Close (TTC) feature not available.
Press and hold the LEARN and CLOSE buttons until the LED
goes out (approximately 3 seconds).
MONITORED ENTRAPMENT PROTECTION DEVICE
To Program:
TTC
LED
AUX ANT
R27
L5
TP1
C20
C9
C29
R24
J2
C21
J4
K2
LT
P1
C32
U4
D7
D6
D5
D4
R25
U1
C31
D14
C18
014A1030
^^^^
D9
LEARN
1
2
3
4
5
6
7
LMEP1
LMEP2
INTRLK
COM
STOP
CLOSE
OPEN
STOP CLOSE OPEN
AUX ANT
Logic Board
Electrical Box
D14
LED
LEARN
1
2
3
4
5
6
7
STOP
CLOSE
OPEN
ALTERNATE INSTALLATION: C2 WIRING TYPE WITHOUT
MONITORED ENTRAPMENT PROTECTION DEVICE
(FACTORY DEFAULT)
• Momentary contact to open and stop with constant pressure to
close.
• Open override that reverses when closing by any opening
device.
• Wiring for entrapment protection device to reverse.
NOTE:
The operator will automatically convert to B2 wiring
when Monitored Entrapment Protection Device is installed.
(See accessories page for Monitored Entrapment Protection
Devices.)
• Timer-to-Close (TTC) feature not available.
NON-MONITORED ENTRAPMENT PROTECTION DEVICE
Sensing Edge
Remove any monitored entrapment protection devices.
Press and hold the LEARN and STOP buttons until LED goes
out (approximately 3 seconds).
Reset to FACTORY DEFAULT (C2) without Monitored Entrapment
Protection Device:
1
1
2
BASIC PROGRAMMING
DETERMINE THE WIRING TYPE
To Reset to B2 with Monitored Entrapment Protection Device:
Press and hold the LEARN and STOP buttons until the LED
goes out (approximately 3 seconds).
1
Summary of Contents for BMT 5011U
Page 10: ...10 OPERATOR NOTES ...