Photoelectric Sensor

ALTERNATE INSTALLATION: C2 WIRING TYPE WITH MONITORED 
ENTRAPMENT PROTECTION DEVICE

•   Momentary contact to open and stop with constant pressure to 

close.

•   Open override that reverses when closing by any opening 

device.

•   Wiring for entrapment protection device to reverse.

NOTE: 

The operator will automatically convert to B2 wiring 

when Monitored Entrapment Protection Device is installed. (See 
accessories page for Monitored Entrapment ProtectionDevices.)

•  Timer-to-Close (TTC) feature not available.

Press and hold the LEARN and CLOSE buttons until the LED 
goes out (approximately 3 seconds). 

MONITORED ENTRAPMENT PROTECTION DEVICE

To Program:

TTC

LED

AUX ANT

R27

L5

TP1

C20

C9

C29
R24

J2

C21

J4

K2

LT

P1

C32

U4

D7

D6

D5

D4

R25

U1

C31

D14

C18

014A1030

^^^^

D9

LEARN

1

2

3

4

5

6

7

LMEP1

LMEP2

INTRLK

COM

STOP

CLOSE

OPEN

STOP CLOSE OPEN

AUX ANT

Logic Board

Electrical Box

D14

LED

LEARN

1

2

3

4

5

6

7

STOP

CLOSE

OPEN

ALTERNATE INSTALLATION: C2 WIRING TYPE WITHOUT 
MONITORED ENTRAPMENT PROTECTION DEVICE 

(FACTORY DEFAULT)

•   Momentary contact to open and stop with constant pressure to 

close.

•   Open override that reverses when closing by any opening 

device.

 •   Wiring for entrapment protection device to reverse.

NOTE: 

The operator will automatically convert to B2 wiring 

when Monitored Entrapment Protection Device is installed. 
(See accessories page for Monitored Entrapment Protection 
Devices.)

•  Timer-to-Close (TTC) feature not available.

NON-MONITORED ENTRAPMENT PROTECTION DEVICE

Sensing Edge

Remove any monitored entrapment protection devices.

Press and hold the LEARN and STOP buttons until LED goes 
out (approximately 3 seconds).

Reset to FACTORY DEFAULT (C2) without Monitored Entrapment 
Protection Device:

1

1

2

BASIC PROGRAMMING

DETERMINE THE WIRING TYPE

To Reset to B2 with Monitored Entrapment Protection Device:

Press and hold the LEARN and STOP buttons until the LED 
goes out (approximately 3 seconds).

1

Summary of Contents for BMT 5011U

Page 1: ...Radio Receiver Built on Board 315 MHz Installation Date MH 5011U MHS 5011U MGJ 5011U MT 5011U BMT 5011U MJ 5011U www liftmaster com CONTACT INFORMATION MEDIUM DUTY LOGIC USER S GUIDE ...

Page 2: ...ored Entrapment Protection Device is installed If the Monitored Entrapment Protection Device is removed the operator will go into a Restricted Close mode Turn power OFF and ON to reset wiring type Restricted close mode requires a constant pressure close command The operator will begin closing after a 5 second delay and will continue to close to the close limit switch The operator will stop if the ...

Page 3: ... Logic Board Electrical Box D14 LED LEARN 1 2 3 4 5 6 7 STOP CLOSE OPEN ALTERNATE INSTALLATION C2 WIRING TYPE WITHOUT MONITORED ENTRAPMENT PROTECTION DEVICE FACTORY DEFAULT Momentary contact to open and stop with constant pressure to close Open override that reverses when closing by any opening device Wiring for entrapment protection device to reverse NOTE The operator will automatically convert t...

Page 4: ...27 D14 COM INTRLK STOP LED OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN R27 AUX ANT AUX ANT AUX ANT D14 COM INTRLK STOP LED OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN 3 BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3 BUTTON CONTROL STATION NOTE The feature will use 3 of the 20 memory channels in the operator 1 2 3 Press and hold the LEARN button LED will ligh...

Page 5: ... 3 4 5 6 7 STOP CLOSE OPEN R27 Every press and release of the STOP button will add 5 seconds to the Timer to Close Example 30 second TTC 6 presses of the STOP button D14 COM INTRLK STOP LED OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN R27 Press and release the TTC button to exit programming mode The LED will flash once per 5 seconds of timer setting D14 COM INTRLK STOP LED OPEN CL...

Page 6: ...Press CLOSE button The door should move in the close direction Release CLOSE button Door should stop if in C2 mode The door should continue closing if in B2 mode Press STOP button The door should stop 1 2 3 TEST 3 BUTTON CONTROL STATION 4 5 Press OPEN button The door should open Allow the door to fully open Press CLOSE button The door should close Allow the door to fully close If the limits are no...

Page 7: ...of the emergency release handle Emergency disconnect will close TO DISCONNECT DOOR FROM OPERATOR TO RECONNECT DOOR ARM TO TROLLEY 1 1 2 3 Emergency Disconnect Door Arm To prevent possible SERIOUS INJURY or DEATH from a falling door or arm DO NOT stand under the door arm when pulling the emergency release If possible use emergency release handle to disengage trolley ONLY when door is CLOSED Weak or...

Page 8: ... hoist operation Refer to Model MJ instructions for emergency operation When the manual chain hoist sash chain is engaged electrical operation will not function 1 2 Keyhole Bracket EMERGENCY DISCONNECT FOR MODELS MJ MODELS MJ AND MGJ This operator has a floor level disconnect chain to disconnect the door from the door operator To disengage pull the chain and secure in the disengaged position by sli...

Page 9: ...uit breaker Accessory failure Verify photoelectric sensors are aligned Possible component failure Contact your installing dealer OPERATOR MAKES NOISE BUT DOOR DOES NOT MOVE Operator requires adjustment Contact your installing dealer DOOR DRIFTS AFTER OPERATOR STOPS Operator or door requires adjustment Contact your installing dealer DOOR OPENS CLOSES TOO FAR Operator requires adjustment Contact you...

Page 10: ...10 OPERATOR NOTES ...

Page 11: ... Button SECURITY Remote Control Includes visor clip Wireless Single Push Button Control SECURITY Rugged composite housing Wireless controls cannot be used in place of hard wired controls 1 2 4 5 7 8 0 3 6 9 333LM WKP5LM3 5 4 digit entry codes WKP250LM3 250 4 digit entry codes 3 Button Tri Colored Dip Switch Remote Control Open Close Stop functionality Includes visor clip Wireless Access Control Ke...

Page 12: ...ed at the Open limit Input functions as Open input at all other times Also used with external radio controls 71 MLMOTION Door In Motion Provides dry contact and a terminal block with contacts switched to power an auxiliary device while the door is in motion 01 34006B ANTENNA EXT ANT Antenna External kit for medium duty 86LM 15 86LMT 25 Antenna Extension Kit The antenna extension kit can be used wi...

Reviews: