INTERRUPT LOOP with Gate Type = Slide or Barrier and ATG disabled
Gate fully open or close:
activation prevents the gate from closing only.
Gate opening or closing:
activation fully opens a closing gate and starts
the Reclose Timer if timer is enabled.
OUTSIDE
INTERRUPT LOOP with ATG disabled
Gate fully open or closed:
activation prevents the gate from closing only.
Gate opening or closing:
activation fully opens the closing gate and starts
the Reclose Timer if timer is enabled.
OUTSIDE
INTERRUPT LOOP with ATG enabled
Gate fully open or closed:
activation prevents the gate from closing only.
Gate opening or closing:
activation prevents the gate from closing. When
the interrupt loop clears, the gate begins closing.
NOTES
♦
If Gate Type = Slide, gate brakes whenever it stops.
♦
If Gate Type = Swing, gate brakes only at open or close limit.
♦
If Gate Type = Barrier, gate never brakes.
INTERRUPT BAR INPUTS (TB11)
INTERRUPT BAR
Activation causes the gate to reverse for a programmable distance
and stop. If Max Retry Count is enabled, gate waits a programmable pause
time, then tries to resume. The gate will retry up to twice before faulting out.
WARNING (TB8)
WARNING OUT Relay contacts close depending on the programmed setting of the warning.
PHONE LINE (J9)
PHONE LINE
Terminals connect the telephone line to the gate operator.
INS/OUTS. INT. SENSE / SHADOW SENSE/ EXIT SENSE (TB12/TB13/TB14/TB15) INPUTS
INSIDE
Input from an Inside Interrupt loop provides the signal for an optional
LiftMaster
INTERRUPT
loop detector add-on board. Operation is the same as the Interrupt Loop
SENSE input,
above.
OUTSIDE
Input from an Outside Interrupt loop provides the signal for an optional
INTERRUPT
LiftMaster loop detector add-on board. Operation is the same as the Interrupt
SENSE
Loop input above.
SHADOW
Input from shadow loop provides signal for optional LiftMaster loop detector
SENSE
add-on board. Operation is the same as Shadow Loop input, above.
EXIT
Input from exit loop provides signal for optional LiftMaster loop detector add-
on
SENSE
board. Operation is the same as Exit Loop input, above.
RADIO INPUT (TB6)
RADIO RECV
Convenience terminals provide power (24VAC, 200mA) and signal
connection for a radio receiver. Activation is the same as Cycle.
MAGLOCK INPUT (TB4)
MAGLOCK
NO
and
COM
inputs can close a circuit (i.e., Maglock) when the Close Limit
switch is activated (the gate is fully closed).