Chamberlain 915GA Install Manual Download Page 7

7

R91 

R94 

R93 

L1 

CLOSE
EDGE

R93 

L1 

D42 

K2 

D1Ø 

OPEN EDGE/

PHOTO

OPEN
PHOTO

CLOSE
PHOTO

Z22 

P1 

F2 

MO

V1 

D1 

Q12 

U4 

CONTROL

INPUTS

FORCE

TIMER TO

CLOSE

OFF

MAX

OPEN

SINGLE BUTTON

RESET

STOP

SHADOW

INTERRUPT

CHGR
OVLD

COM

COM

CTRL

LOOP

INPUTS

D129 

Z4 

U3
 

D2 

D44 

C11 

C13 

C12 

D16 

F9 

R1Ø1 

R1ØØ 

K1 

Q22 

F3 

K3 

K4 

R196 

F1 

Z12 

GATE 2

ACCESSORY

POWER

ALARM

GATE 1

MAGR

SOL

GR

WH

YL

BL

RD

BR

GR

WH

YL

BL

RD

BR

F7 

24V

CTRL
OVLD

TIMER

RUNNING

GATE 2

SET

OPEN
LIMIT

SET

CLOSE

LIMIT

LEARN
LIMITS

DIAGNOSTIC

GATE 1

LEARN

XMITTER

LOCK /

ON

OFF

PWR

C69 

OFF

MAX

J2
Ø 

PWR

SINGLE BUTTON

AC PWR
/SOLAR

D8 

D4 

R9 

R329 

R27 

MO

V2 

R4 

C2 

BIPART DELAY

LOCK

GND

Z1 

R1 

R2 

K5 

F12 

Q9 

R9Ø 

F8 

Q6 

Q1 

J19 

ACCESSORY

0VLD

R182 

C1Ø1 

C75 

C73 

C72 

C71 

C7Ø 

C66 

C65 

C68 

C33 

F11 

R186 

R42Ø 
R423 

J24      J23      3

Ø

A      32V 

 3

Ø

A    32V 

J21 

30 

30 

C64 

R22 

U2 

J18 

K6 

JU1 

JU2 

DB1 

D36 

R184 

Control Box

Control Board

K2 

D1Ø 

DIAGNOSTIC

XMITTER

BIPART DELAY

C73 

C72 

C71 

C7Ø 

PROGRAMMING

Reprogram Limits

 1. 

Press 

the 

LEARN LIMITS

 button.

 2. 

The 

SET OPEN LIMIT

 LED will blink.

 3. 

 

Use 

the 

GATE 1

 buttons to move gate 1 to the 

desired open position. Repeat if gate 2 is present 
using 

GATE 2

 buttons.

 4. 

 

Press 

the 

LEARN LIMITS

 button to set the open 

limit for gate(s).

 5. 

 

The 

SET OPEN LIMIT

 LED will turn off. The 

SET 

CLOSE LIMIT

 LED will blink.

 6. 

 

Use 

the 

GATE 1

 buttons to move gate 1 to the 

desired close position. Repeat if gate 2 is present 
using 

GATE 2

 buttons.

 7. 

 

Press 

the 

LEARN LIMITS

 button to set the close 

limit for the gate(s).

 8. 

 

The 

SET CLOSE LIMIT 

LED will turn off. The limits 

are now set.

  9.  Using a programmed remote control or single 

button control (SBC) run the gate(s) from the 
close limit to the open limit. After reaching the 
open limit, run the gate(s) to the close limit. This 
will program the force in the open and close 
direction.

Control Box

Screws

SECURE CONTROL BOX

Close the control box cover and secure with the four screws.

K2 

D1Ø 

K1 

R

GATE 2

SET

OPEN

LIMIT

SET

CLOSE

LIMIT

LEARN

LIMITS

DIAGNOSTIC

GATE 1

XMITTER

BIPART DELAY

Q9 

C73 

C72 

C71 

C7Ø 

Summary of Contents for 915GA

Page 1: ... lock If installing the gate lock on a Push to Open gate the gate lock must be installed on the opposite side of the gate PULL TO OPEN GATE PUSH TO OPEN GATE Gate Bracket Pin Cotter Pin Gate Bracket Gate Lock Washer Keys 2 Cable Ties 6 Watertight Connector 1 CARTON INVENTORY To avoid SERIOUS personal INJURY or DEATH from electrocution Disconnect ALL electric and battery power BEFORE performing ANY...

Page 2: ...2 Q22 F3 F3 K3 K3 K4 K4 R196 R196 F1 F1 Z12 Z12 GATE 2 GATE 2 GATE 1 GATE 1 MAGR MAGR SOL SOL GR GR WH WH YL YL BL BL RD RD BR BR GR GR WH WH YL YL BL BL RD RD BR BR F7 F7 24V 24V CTRL CTRL OVLD OVLD TIMER TIMER RUNNING RUNNING GATE 2 GATE 2 SET SET OPEN OPEN LIMIT LIMIT SET SET CLOSE CLOSE LIMIT LIMIT LEARN LEARN LIMITS LIMITS GATE 1 GATE 1 LEARN LEARN XMITTER XMITTER LOCK LOCK ON ON OFF OFF C69 ...

Page 3: ...in Carriage Bolts Nuts Washers Washer Cotter Pin Gate Bracket Pin Washer Cotter Pin NOTE For chain link and other fencing additional reinforcement may be needed to properly support the gate lock see below 5 Mount the gate bracket using hardware not provided Hand tighten the nuts 6 Insert the gate bracket pin through the gate bracket 8 Mount the gate lock using hardware not provided 7 Slide the was...

Page 4: ...trol box by loosening the four screws 2 Run the wire back to the control box Use the cable ties to secure the wire to the gate NOTE Make sure that the gate does not pinch bind or rub the wire Make sure that the wire does not sag or touch the ground Never run the wire along the bottom edge of the gate between the gate and the ground 3 Feed the wire into the control box through an available knockout...

Page 5: ...RED BRN GRN WHT YEL BLU RED BRN F4 10A 32V F7 24V COM OVLD TIMER RUNNING GATE 2 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS DIAGNOSTIC GATE 1 J4 LEARN XMITTER MAGLOCK ON OFF C71 C7Ø ON OFF LOCK BIPART DELAY Z22 R91 CLOSE EDGE R94 R92 R93 L1 R1 R2 Z1 K5 K6 K2 F3 10A 32V D1Ø OPEN EDGE PHOTO OPEN PHOTO CLOSE PHOTO R227 R2Ø7 Z2Ø R223 P1 Z9 Z8 F2 F6 D4 D2 R9 C64 JMPR1 R224 U4 CONTROL INPUTS FORCE TIMER...

Page 6: ... BL BL RD RD BR BR F7 F7 24V 24V CTRL CTRL OVLD OVLD TIMER TIMER RUNNING RUNNING GATE 2 GATE 2 SET SET OPEN OPEN LIMIT LIMIT SET SET CLOSE CLOSE LIMIT LIMIT LEARN LEARN LIMITS LIMITS GATE 1 GATE 1 LEARN LEARN XMITTER XMITTER LOCK LOCK ON ON OFF OFF C69 C69 OFF OFF MAX MAX J2 J2Ø PWR PWR AC PWR AC PWR SOLAR SOLAR D8 D8 D4 D4 R9 R9 R329 R329 R27 R27 BIPART DELAY BIPART DELAY LOCK LOCK GND GND Z1 Z1 ...

Page 7: ...C72 C71 C7Ø PROGRAMMING Reprogram Limits 1 Press the LEARN LIMITS button 2 The SET OPEN LIMIT LED will blink 3 Use the GATE 1 buttons to move gate 1 to the desired open position Repeat if gate 2 is present using GATE 2 buttons 4 Press the LEARN LIMITS button to set the open limit for gate s 5 The SET OPEN LIMIT LED will turn off The SET CLOSE LIMIT LED will blink 6 Use the GATE 1 buttons to move g...

Page 8: ...e gate when manually opening the gate lock The gate lock does not activate fast enough to release the bracket pin in order to allow the gate to open 1 The gate may be moving too quickly for the gate lock to properly activate Set the Lock Bipart delay to the ON position 2 The gate bracket pin may be binding and preventing the lock from properly sliding Verify that the bracket and gate lock are prop...