background image

2

3

NOTE:  

Before you start modification, test all operator

functions.

COMPONENT MOUNTING

1.    Install  the  four  pole  terminal  block  on  the  side  of
the electrical box opposite the limit switches using the
existing holes in the box and the (2) #8-32 x 5/8” pan
head phillips and (2) #8 serrated flange nuts supplied.
Label this 1A, 2A, 3A and 4A.

2.  Install the long distance control module to the side
wall  of  the  electrical  box  using  the  velcro  located  on
the back of the module.  Be sure that the placement
of  the  module  is  central  to  the  new  four  pole  and
existing ten pole terminal block.

COMPONENT WIRING

1.  Connect the orange wire from the controls side of
the module to 4A on the new four pole terminal block.
Move the push button field wire from terminal 4 to the
new terminal 4A.

2.  Connect the yellow wire from the controls side of
the module to 3A on the new four pole terminal block.
Move the push button field wire from terminal 3 to the
new terminal 3A.

3.    Connect  the  green  wire  from  the  controls  side  of
the module to 1A on the new four pole terminal block.
Move the push button field wire from terminal 1 to the
new terminal 1A.

4.  Connect the blue wire from the controls side of the
module  to  2A  on  the  new  four  pole  terminal  block.
Move the push button field wire from terminal 2 to the
new terminal 2A.

5.  Connect one black wire from the operator side of
the  module  to  terminal  5  on  the  10  pole  terminal
block.

6.    Connect  the  other  black  wire  from  the  operator
side  of  the  module  into  the  orange  wire  nut  that  is
already  in  the  operator.    This  wire  nut  has  one
orange, one purple, one yellow and at least 1 red wire
nut.

7.  Connect the green wire from the operator side of
the  module  to  terminal  1  on  the  10  pole  terminal
block.

8.  Connect the blue wire from the operator side of the
module to terminal 2 on the 10 pole terminal block.

INSTALLATION INSTRUCTIONS

(DOOR OPERATORS W/ THREE BUTTON CONTROL STATION)

9.    Connect  the  white  wire  from  the  operator  side  of
the  module  to  terminal  3  on  the  10  pole  terminal
block.

10.    Connect  the  red  wire  from  the  operator  side  of
the  module  to  terminal  4  on  the  10  pole  terminal
block.    For  additional  wiring  help  refer  to  figure  2
below.

11.    Wire  push  button  wires  only  to  1A,  2A,  3A  and
4A.

NOTE:  

For additional wiring help refer to figure 1.

WARNING

DO NOT CONNECT ANY OTHER TERMINALS IN

THE OPERATOR TO TERMINALS 1A, 2A, 3A, OR

4A.    ACCIDENTALLY  CROSSING  TERMINALS

WILL DAMAGE THE LONG DISTANCE MODULE.

       TO CONTROLS

T3     T4    T2    T1                     T5

Stop

Close

WH     RD    BL   GN       BK    BK

BL           GN      YE             OR

  2A            1A     3A              4A

TO OPERATOR

Existing orange wire nut in operator

Open

FIGURE 1

NOTE:  

Before you start modification, test all operator

functions.

COMPONENT MOUNTING

Install the long distance control module to the side of
the enclosure using the velcro located on the back of
the  module.    Be  sure  that  the  placement  of  the
module is central to the S3 board (for models SL540
and SL570 place module central to the terminal block
located in the control box).

COMPONENT WIRING

1.  Connect the orange wire from the controls side of
the  module  to  Stop  (NC)  on  the  control  station  with
one of the orange wire nuts supplied.

2. Connect the blue wire from the controls side of the
module to Close (NO) on the control station with one
of the orange wire nuts supplied. 

3.    Connect  the  green  wire  from  the  controls  side  of
the  module  to  Open  (NO)  on  the  control  station  with
one of the orange wire nuts supplied.  

4.  Connect the yellow wire from the controls side of
the  module  to  (COM)  on  the  control  station  with  one
of the orange wire nuts supplied.

5.  Connect the black wires from the operator side of
the  module  to  24VAC  (may  connect  to  R1  and  R3
terminals in the operators).

6.  Connect the green wire from the operator side of
the  module  to  J1-6  on  the  S3  board  (for  Models
SL540 and SL570 connect wire to T7 on the terminal
block located in the control box).

7.  Connect the blue wire from the operator side of the
module  to  J1-4  on  the  S3  board  (for  Models  SL540
and  SL570  connect  wire  to  T4  on  the  terminal  block
located in the control box).  Move position 1 on switch
SW1 to ON position.

INSTALLATION INSTRUCTIONS

(GATE OPERATORS W/ THREE BUTTON CONTROL STATION)

TO   CONTROLS

J1-5     J1-3    J1-4   J1-6

Stop

Close

Open

WH    RD     BL    GN     BK     BK

BL           GN           YE        OR

TO   OPERATOR

24 VAC

FIGURE 3

8.  Connect the red wire from the operator side of the
module  to  J1-3  on  the  S3  board  (for  Models  SL540
and  SL570  connect  wire  to  T3  on  the  terminal  block
located in the control box).

9.    Connect  the  white  wire  from  the  operator  side  of

the  module  to  J1-5  on  the  S3  board  (for  Models

SL540 and SL570 connect wire to T5 on the terminal

block located in the control box).

NOTE:  

For additional wiring help refer to figure 3.

Reviews: