2
3
NOTE:
Before you start modification, test all operator
functions.
COMPONENT MOUNTING
1. Install the four pole terminal block on the side of
the electrical box opposite the limit switches using the
existing holes in the box and the (2) #8-32 x 5/8” pan
head phillips and (2) #8 serrated flange nuts supplied.
Label this 1A, 2A, 3A and 4A.
2. Install the long distance control module to the side
wall of the electrical box using the velcro located on
the back of the module. Be sure that the placement
of the module is central to the new four pole and
existing ten pole terminal block.
COMPONENT WIRING
1. Connect the orange wire from the controls side of
the module to 4A on the new four pole terminal block.
Move the push button field wire from terminal 4 to the
new terminal 4A.
2. Connect the yellow wire from the controls side of
the module to 3A on the new four pole terminal block.
Move the push button field wire from terminal 3 to the
new terminal 3A.
3. Connect the green wire from the controls side of
the module to 1A on the new four pole terminal block.
Move the push button field wire from terminal 1 to the
new terminal 1A.
4. Connect the blue wire from the controls side of the
module to 2A on the new four pole terminal block.
Move the push button field wire from terminal 2 to the
new terminal 2A.
5. Connect one black wire from the operator side of
the module to terminal 5 on the 10 pole terminal
block.
6. Connect the other black wire from the operator
side of the module into the orange wire nut that is
already in the operator. This wire nut has one
orange, one purple, one yellow and at least 1 red wire
nut.
7. Connect the green wire from the operator side of
the module to terminal 1 on the 10 pole terminal
block.
8. Connect the blue wire from the operator side of the
module to terminal 2 on the 10 pole terminal block.
INSTALLATION INSTRUCTIONS
(DOOR OPERATORS W/ THREE BUTTON CONTROL STATION)
9. Connect the white wire from the operator side of
the module to terminal 3 on the 10 pole terminal
block.
10. Connect the red wire from the operator side of
the module to terminal 4 on the 10 pole terminal
block. For additional wiring help refer to figure 2
below.
11. Wire push button wires only to 1A, 2A, 3A and
4A.
NOTE:
For additional wiring help refer to figure 1.
WARNING
DO NOT CONNECT ANY OTHER TERMINALS IN
THE OPERATOR TO TERMINALS 1A, 2A, 3A, OR
4A. ACCIDENTALLY CROSSING TERMINALS
WILL DAMAGE THE LONG DISTANCE MODULE.
TO CONTROLS
T3 T4 T2 T1 T5
Stop
Close
WH RD BL GN BK BK
BL GN YE OR
2A 1A 3A 4A
TO OPERATOR
Existing orange wire nut in operator
Open
FIGURE 1
NOTE:
Before you start modification, test all operator
functions.
COMPONENT MOUNTING
Install the long distance control module to the side of
the enclosure using the velcro located on the back of
the module. Be sure that the placement of the
module is central to the S3 board (for models SL540
and SL570 place module central to the terminal block
located in the control box).
COMPONENT WIRING
1. Connect the orange wire from the controls side of
the module to Stop (NC) on the control station with
one of the orange wire nuts supplied.
2. Connect the blue wire from the controls side of the
module to Close (NO) on the control station with one
of the orange wire nuts supplied.
3. Connect the green wire from the controls side of
the module to Open (NO) on the control station with
one of the orange wire nuts supplied.
4. Connect the yellow wire from the controls side of
the module to (COM) on the control station with one
of the orange wire nuts supplied.
5. Connect the black wires from the operator side of
the module to 24VAC (may connect to R1 and R3
terminals in the operators).
6. Connect the green wire from the operator side of
the module to J1-6 on the S3 board (for Models
SL540 and SL570 connect wire to T7 on the terminal
block located in the control box).
7. Connect the blue wire from the operator side of the
module to J1-4 on the S3 board (for Models SL540
and SL570 connect wire to T4 on the terminal block
located in the control box). Move position 1 on switch
SW1 to ON position.
INSTALLATION INSTRUCTIONS
(GATE OPERATORS W/ THREE BUTTON CONTROL STATION)
TO CONTROLS
J1-5 J1-3 J1-4 J1-6
Stop
Close
Open
WH RD BL GN BK BK
BL GN YE OR
TO OPERATOR
24 VAC
FIGURE 3
8. Connect the red wire from the operator side of the
module to J1-3 on the S3 board (for Models SL540
and SL570 connect wire to T3 on the terminal block
located in the control box).
9. Connect the white wire from the operator side of
the module to J1-5 on the S3 board (for Models
SL540 and SL570 connect wire to T5 on the terminal
block located in the control box).
NOTE: