CONTENTS

Preparation .............................. 1-4
Assembly ................................. 5-9

Installation ............................ 10-17
Install the Door Control ............. 18-19

Install the Protector System

®

 ...... 20-23

Power  .................................. 24-25

Adjustments .......................... 26-28

Operation.................................. 29

Features ................................... 30

Remote Control .......................... 31

To Erase the Memory .................... 32

To Open the Door Manually ............ 32

Maintenance .............................. 33

Diagnostic Chart ......................... 34

Warranty .................................. 35

Chain Drive
Garage Door Opener

■ 

 Please read this manual and the enclosed safety materials carefully!

  Fasten the manual near the garage door after installation.

■ 

  The door WILL NOT CLOSE unless the Protector System

®

 is connected and 

properly aligned.

  Periodic checks of the garage door opener are required to ensure safe operation.

  The model number label is located on the back panel of your garage door opener.

  This garage door opener is compatible with Security

 2.0™ accessories.

   WARNING: To reduce the risk of injury to persons – Use this opener ONLY with a 

7 foot sectional door.

Serial Number:

Date of Purchase:

 

Model Number: 

Models HD220, HD220C, 
PD220, PD222, and LW260C

FOR RESIDENTIAL USE ONLY 

INSTALL ON 7 FOOT 
SECTIONAL DOORS ONLY

Register your new garage door opener at 
www.prodregister.com/chamberlain or 
scan the QR code with your smartphone

Write down the following information 
for future reference:

Summary of Contents for 8010WLA

Page 1: ...tion The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the garage door opener are required to ensure safe operation The model number label is loc...

Page 2: ...ove or adjustgarage door door springs cables pulleys brackets or their hardware ALL ofwhich are under EXTREME tension l Disable ALL locks and remove ALL ropes connected to garage door BEFORE installat...

Page 3: ...ished ceiling in your garage n EXTENSION BRACKETS MODEL 041A5821 1 OR WOOD BLOCKS Depending upon garage construction extension brackets or wood blocks may be needed to install the safety reversing sen...

Page 4: ...bracket 41A5047 1 B Pulley In hardware bag C Door bracket 41A5047 D Curved door arm E Straight door arm Packaged inside front rail section F Trolley NOTE Be sure to assemble the trolley before slidin...

Page 5: ...x1 1 2 Ring Fastener 4 Hex Bolt 1 4 20x3 4 4 Lock Washer 5 16 Hex Nuts 5 16 2 Self Threading Screw 1 4 14x5 8 2 Clevis Pin 5 16 x1 Clevis Pin 5 16 x1 1 4 Carriage Bolt 1 4 20x1 2 2 Wing Nut 1 4 20 2...

Page 6: ...se these grooves to align the rail sections Slide the tapered ends into the larger ones Tabs along the side will lock into place 3 As a temporary stop inserta screwdriver into the hole in the second r...

Page 7: ...d ofthe rail 2 Ensure thatthe chain spreader is installed 3 Place the rail onto the motor unit Align the screw holes in the rail with the holes on top ofthe motor unit 4 Use a 1 4 socketto fasten the...

Page 8: ...to ensure proper operation 3 Place the idler pulley into the window as shown 4 Secure idler pulley with clevis pin and ring fastener 5 Rotate the pulley to be sure itspins freely 6 Locate the rail tab...

Page 9: ...er dispense the remainder ofthe cable chain along the rail toward the motor unitinto the sloton the chain spreader around the sprocketonto the chain spreader and continuing to the trolley assembly The...

Page 10: ...n installation is complete you may notice some chain droop with the door closed This is normal Ifthe chain returns to the position shown when the door is open do notre adjustthe chain NOTES During fut...

Page 11: ...83 m above the floor and avoiding contactwith vehicles to avoid accidental release 7 NEVER connectgarage door opener to power source until instructed to do so 8 NEVER wear watches rings or loose cloth...

Page 12: ...door You can fasten the header bracketwithin 4 feet 1 22 m ofthe leftor rightofthe door center only ifa torsion spring or center bearing plate is in the way or you can attach itto the ceiling when cle...

Page 13: ...ral supportwith the hardware provided UP Wall Mount Optional Mounting Holes Vertical Centerline of Garage Door Header Wall Header Bracket 2x4 Structural Support Door Spring Garage Door Highest Point o...

Page 14: ...damage to garage door restgarage door opener rail on 2x4 placed on top section ofdoor 1 Remove the packing material and liftthe garage door opener onto a ladder 2 Fully open the door and place a 2x4 l...

Page 15: ...1 4 20x3 4 1 On finished ceilings use the 14 10x1 1 2 lag screws to attach a supportbracket notprovided to the structural supports before installing the garage door opener 2 Make sure the garage door...

Page 16: ...eventpossible SERIOUS INJURY or DEATH from a falling garage door l Ifpossible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced doo...

Page 17: ...stamped inside the bracket 2 Position the top edge ofthe bracket2 4 5 10 cm below the top edge ofthe door OR directly below any structural supportacross the top ofthe door 3 Mark drill holes and inst...

Page 18: ...ther Find two pairs ofholes thatline up and join sections Selectholes as far apartas possible to increase door arm rigidity and attach using the bolts and nuts 5 Pull the emergency release handle towa...

Page 19: ...Activate door ONLY when itcan be seen clearly is properly adjusted and there are no obstructions to door travel l ALWAYS keep garage door in sightuntil completely closed NEVER permitanyone to cross p...

Page 20: ...sulation from the end ofthe wire near the garage door opener 3 Connectthe wire to the red and white terminals on the garage door opener Ifyour garage is pre wired make sure you use the same wires that...

Page 21: ...EDs will light The garage door opener will notgo into the sleep mode until the garage door opener has completed 5 cycles upon power up When installing the safety reversing sensors check the following...

Page 22: ...The lenses on both sensors should pointtoward each other Make sure the lens is notobstructed by the sensor bracket Not provided No more than 6 inches 15 cm 1 2 Inside Garage Wall Not provided Lens Car...

Page 23: ...er Attach the wire to the wall and ceiling with the staples 2 Strip 7 16 inch 11 mm ofinsulation from each setofwires Separate the wires Twistthe white wires together Twistthe white black wires togeth...

Page 24: ...nectto the yellow wire and the white black wire would connectto the purple wire 4 Atthe garage door opener strip 7 16 inch 11 mm ofinsulation from each end ofthe wires previously chosen for the safety...

Page 25: ...et 2 DO NOT run garage door opener atthis time OPTION B PERMANENT WIRING If permanent wiring is required by yourlocalcode referto the following procedure To make a permanent connection through the 7 8...

Page 26: ...wing nuts Green LED Amber LED If the receiving sensor is in direct sunlight switch it with sending sensor so it is on the opposite side of the door invisible light beam SENDING SENSOR RECEIVING SENSO...

Page 27: ...the door will stop in the open UP and close DOWN position The electronic controls sense the amountofforce required to open and close the door The force is adjusted automatically when you program the t...

Page 28: ...tton until the door is in the desired DOWN position 5 Once the door is in the desired DOWN position press and release the AdjustmentButton The garage door opener lights will flash twice and the UP But...

Page 29: ...he 1 1 2 inch board remove the board and open close the door 3 or 4 times to testthe adjustment Ifthe garage door opener continues to fail the safety reversal test call a trained door systems technici...

Page 30: ...dly and or unexpectedly and increasing the risk ofSEVERE INJURY or DEATH 7 NEVER use emergency release handle unless garage doorway is clear ofpersons and obstructions 8 NEVER use handle to pull garag...

Page 31: ...ing sensors are notinstalled or are misaligned the door will notclose from a remote control However you can close the door ifyou hold the button on the door control or keyless entry until the door is...

Page 32: ...r press the push button until the garage door opener activates itmay take up to 3 presses Push Button Remote Control Yourremote controlhas been programmed at the factory to operate with yourgarage doo...

Page 33: ...an open door falling rapidly and or unexpectedly l NEVER use emergency release handle unless garage doorway is clear ofpersons and obstructions l NEVER use handle to pull door open or closed Ifrope kn...

Page 34: ...ow the remote control s LED will notflash when the button is pressed To replace battery pry open the case firstin the middle 1 then at each side 2 and 3 with the visor clip Replace the batteries with...

Page 35: ...rrectas needed Check wiring connections attravel module and atthe logic board Replace unitifnecessary No movement only a single click Manually open and close the door Check for binding or obstructions...

Page 36: ...arts at Seller s sole option ALL IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION...