INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a minimum
height of 5

'

 (1.5 m) where small children cannot reach,

away from moving parts of door and door hardware. If
installing into drywall, drill 5/32" holes and use the anchors
provided. For pre-wired installations (as in new home
construction), it may be mounted to a single gang box
(Figure 1).

NOTE: 

The functional temperature range of the door

control is between -4° F (-20° C) and 122° F (50° C).
Scroll speed of display is slower at lower temperatures
although the door control remains fully functional.

CAUTION: 

Continuous exposure of the door control to

temperatures below -22° F (-30° C) may damage the LCD
screen.

SPECIAL NOTE:

Only one 398LM can be connected to

each garage door opener. If additional wall controls are
desired to operate the same garage door opener, it is
recommended to use model 378LM wireless wall control
as the secondary control console. 

1. Strip 7/16" (11 mm) of insulation from one end of bell

wire and connect to the two screw terminals on back of
door control by color: white wire to the W (2) and
white/red wire to the R (1) (Figure 2).

2. Remove push bar cover by gently prying at the

lower/middle portion of the cover with a small flat-head
screwdriver. Fasten with 6AB x 1-1/4" self-tapping
screws (drywall installation) or 6-32 x 1" machine
screws (into gang box) as follows:

• Install bottom screw, allowing 1/8" (3 mm) to protrude

above wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid cracking

plastic housing. 

DO NOT overtighten.

• Replace cover by inserting top tabs first and then snap

cover in place.

3.

(For standard installations ONLY)

Run bell wire up

wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. DO NOT pierce
wire with a staple, creating a short or open circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals on the
motor unit: white to white and white/red to red
(Figure 2). To release or insert wire, push in tab with
screwdriver tip.

NOTE:

If you have any trouble with the operation of the

buttons, loosen the top mounting screw. DO NOT connect
power and operate the opener at this time.The trolley will
travel to the full open position but will not return to the
close position until the sensor beam is connected and
properly aligned.

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires. 
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach

of children at a minimum height of 5 feet (1.5 m), and away
from all moving parts of door.

• NEVER permit children to operate or play with door control

push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is properly

adjusted, and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

Drywall Anchors

Insulated
Staples 

Screw 6ABx1-1/4" 
(std installation)

Screw 6-32x1" 
(pre-wired)

HARDWARE SHOWN ACTUAL SIZE

Strip 

w

ire 7/16"

7/16" (11 mm)

Red

Grey

W

hite

Q

u

ick-Connect

Terminals

Antenna 

To release or insert 

w

ire,

p

u

sh in ta

b

 

w

ith

scre

w

dri

v

er tip

Door Control
Connections

P

u

sh Bar

Light 
B

u

tton

Lock
B

u

tton

Door
Control
Terminal
Scre

w

s

(BACK VIE

W

)

W

2

R
1

2-Cond

u

ctor

Bell 

W

ire

LOCK

LOCK

Figure 2

PRE-WIRED INSTALLATION

REMOVE & REPLACE COVER

To Replace Insert 
Top Tabs First

Push Bar Cover

24 Volt Bell Wire

LOCK

LIGHT

LOCK

LIGHT

Figure 1

Summary of Contents for 3585 3/4

Page 1: ...ease read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properl...

Page 2: ...roblem 30 Diagnostic chart 31 Smart Control PanelTM messages 32 Programming 33 34 To add or reprogram a hand held remote control 33 To erase all codes from motor unit memory 33 3 Button remotes 33 To...

Page 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Page 4: ...s page and the accompanying illustrations as you proceed with the installation of your opener Access Door Safety Reversing Sensor Safety Reversing Sensor Gap between floor and bottom of door must not...

Page 5: ...ulley Bracket Belt Trolley SECURITY 3 Button Remote Control Model 373P 1 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Safety Senso...

Page 6: ...it sprocket 6 ASSEMBLY STEP 2 Set the Belt Tension By hand thread the spring trolley nut on the threaded shaft until it is finger tight against the trolley Figure 1 Do not use any tools Insert a screw...

Page 7: ...ner mechanisms 9 Install wall mounted garage door control within sight of the garage door out of reach of children at minimum height of 5 feet 1 5 m away from ALL moving parts of the door 10 Place ent...

Page 8: ...he top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible S...

Page 9: ...et either to the wall above the garage door or to the ceiling Follow the instructions which will work best for your particular requirements Do not install the header bracket over drywall If installing...

Page 10: ...tach the Rail to the Header Bracket Position the opener on the garage floor below the header bracket Use packing material as a protective base NOTE If the door spring is in the way you ll need help Ha...

Page 11: ...r setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place...

Page 12: ...s not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket 8 Grease the top and underside of the rail surface where the trolley slides...

Page 13: ...all and across ceiling to motor unit Use insulated staples to secure wire in several places DO NOT pierce wire with a staple creating a short or open circuit 4 Strip 7 16 11 mm of insulation from end...

Page 14: ...arm of the outer trolley Adjust rope length so the handle is 6 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure with an overhand knot...

Page 15: ...g cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be ground...

Page 16: ...iving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be se...

Page 17: ...the floor Attach brackets to wall with lag screws Not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure...

Page 18: ...NSORS Plug in the opener The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow...

Page 19: ...epending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracke...

Page 20: ...M STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED Self Threading Screw 1 4 14x5 8 HARDWARE SHOWN ACTUAL SIZE 20 ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on...

Page 21: ...re 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Brin...

Page 22: ...l push button The trolley will travel to the fully closed position Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm connector ho...

Page 23: ...s explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 3 7 5 cm of travel If door still won t...

Page 24: ...kwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to...

Page 25: ...e obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAF...

Page 26: ...ht feature on the Smart Control PanelTM is activated Bulb size is A19 Bulb power is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door Wi...

Page 27: ...isable the motion sensor when using the opener lights as working lights Otherwise they will turn off automatically if you are working beyond the sensors range Lock feature Designed to prevent operatio...

Page 28: ...n on the Smart Control PanelTM 3 Press and hold the Lock button on the Smart Control PanelTM 4 After the opener lights flash release all buttons Test by pressing the remote push button The opener ligh...

Page 29: ...le and lift the door manually To reconnect the door to the opener press the door control push bar The lockout feature prevents the trolley from reconnecting automatically Pull the emergency release ha...

Page 30: ...justments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adj...

Page 31: ...touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with j...

Page 32: ...on the Smart Control Panel Pressing the Prog LEARN button again will allow the user to program an additional remote control to the opener Meaning This message will appear when the Prog learn button ha...

Page 33: ...n indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate your garage door 3 Release the button when the motor...

Page 34: ...ot the last temporary PIN then press and hold the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then press Enter The opener light...

Page 35: ...tton remote control 3 10A19 3V2016 Lithium battery LED and opener 4 10A33 3V2016 Lithium battery proximity switch 5 29C151 Remote control visor clip 6 41A2828 Emergency release rope and handle assembl...

Page 36: ...56uF 8B 30B529 Capacitor 40uF 8C 41A5637 Resistor 9 41A3150 Terminal block w screws 10 41D5563 1 Universal replacement motor bracket assembly Complete with Motor worm bracket gear case bearing assemb...

Page 37: ...y from home and turn opener lights on or off from the door control Garage Door Monitor Security for the largest door of your home Tells you if your garage door is open or closed Monitors up to 4 garag...

Page 38: ...38 NOTES...

Page 39: ...39 NOTES...

Page 40: ...ller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or...

Reviews: