I-HDL106-02.doc
Issue 11 11/05/2020
2
IOM
– HDL106 Luminaire (ATEX & IECEx)
Type Of Protection
Ex e mb (Increased safety,encapsulation), Ex tb (dust)
Protection Standards
(IEC) EN 60079-0, (IEC) EN 60079-7, (IEC) EN 60079-18, (IEC) EN 60079-31
Area Classification
Zone 1 and Zone 2 areas to (IEC) EN 60079-10-1
Zone 21 and Zone 22 areas to (IEC) EN 60079-10-2
Installation
(IEC) EN 60079-14
Certificate
IECEx Certificate of Conformity IECEx SIR 09.0064X
EU - Type Examination Certificate Sira 09ATEX5159X
Equipment Coding
HDL106N
100V to 254V 50/60Hz
HDL106N
18V to 54V AC/DC
HDL106A
Ex e mb llC T4 Gb
Ex tb lllC T103°C Db IP6X
-20°≤ Ta ≤+50°C
or
Ex e mb llC T3 Gb
Ex tb lllC T103°C Db IP6X
-20°≤ Ta ≤+59.5°C
Ex e mb llC T4 Gb
Ex tb lllC T87°C Db IP6X
-20°≤ Ta ≤+55°C
Ex e mb llC T6 Gb
Ex tb lllC T70°C Db IP6X
-20°≤ Ta ≤+50°C
or
Ex e mb llC T5 Gb
Ex tb lllC T85°C Db IP6X
-20°≤ Ta ≤+65°C
ATEX Coding
II 2GD
Ingress Protection
IP66/67
Laser safety class
Class 1 LED product
CE Mark
The CE marking of this product applies to "The Electrical Equipment (Safety) Regulations
2006", "The Electromagnetic Compatibility Regulations 2004", the “Waste Electrical and
Electronic Equipment Regulations 2006” and the "Equipment and Protective Systems intended
for use in Explosive Atmospheres Regulations 1996". [This legislation is the equivalent in UK
law of EU directives 2014/35/EU, 2014/30/EU, 2012/19/EU and 2014/34/EU respectively].
The Equipment is declared to meet the provisions of the ATEX directive (2014/34/EU)
by reason of the EU Type Examination and compliance with the Essential Health and
Safety Requirements.
M Poutney Technical Manager
SPECIFIC CONDITIONS OF USE
(denoted by X after the certificate number).
1. Except for internal wiring, not more than one single or multiple strand lead shall be connected into either side
of any terminal, unless multiple conductors have been joined in a suitable manner, e.g. two conductors into a
single insulated crimped boot lace ferrule.
2. Leads connected to the terminals shall be insulated for the appropriate voltage and this insulation shall
extend to within 1 mm of the metal of the terminal throat.
3. When terminals in accordance with certificate Sira 01ATEX3247U are used, all terminal screws, used and
unused, shall be tightened down to between 0.5 Nm and 0.7 Nm.
4. When terminals in accordance with certificate Sira 01ATEX3249U are used, all terminal screws, used and
unused, shall be tightened down to between 1.2 Nm and 2 Nm.
5. When terminals in accordance with certificates Sira 01ATEX3247U and Sira 01ATEX3249U are used, they
shall only be installed and wired with cable within a temperature range of -10°C to 80°C.
6. When cross-connecting combs are used on terminals to certificates Sira 01ATEX3247U and
Sira 01ATEX3249U, the relevant conditions associated with those certificates shall be applied.
7. Cable entry holes shall be fitted with either an appropriately certified cable gland or appropriately certified
blanking element. These shall provide and maintain a minimum enclosure ingress protection of IP66 or
IP67 as appropriate.
8. If more than 8 individual LEDs are not illuminated, the LED assembly shall be replaced.
9. The supply circuit must be protected by a fuse capable of withstanding a prospective short circuit
current of 1500 A.
10. When the Lexan polycarbonate lens is fitted, the equipment shall only be used in areas with a low risk of
mechanical impact.
11.Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of this equipment
may generate an ignition-capable level of electrostatic charge. Therefore the equipment shall not be installed
in a location where the external conditions are conducive to the build-up of electrostatic charge on such
surfaces. In addition, the equipment shall only be cleaned with a damp cloth.