ChallengerOptics CO-OPM-MPO12 Operating Manual Download Page 9

Challenger

Optics.com

Wavelength Specific Optical Testing and Measurement Equipment

Challenger

Optics.com

Wavelength Specific Optical Testing and Measurement Equipment

Chapter 2.3 - Menu

   /   18

Chapter 2.3 - Menu

   /   17

2.3.9  Scan Display

‘Scan Display’ consists of  ‘All’ 
and ‘Measured’ .

This can be selected using 
               ,                .

‘All’ will display power level on 
all 12 fibers .

If you choose ‘Measured’, only active fibers 
will be displayed .

5     jkl

8     tuv

2.3.8  Scan type

This option allows the user  
to choose the scan type:
Press & Scan (Single) or  
Real Time using  
the 

          

 and 

        

   

keys, 

user can toggle between a 
single scan or continuous 
(real time) scan when you 
press the            button.

 

5     jkl

8     tuv

SCAN

3     def

2.3.10  Threshold

This will change the baseline of 
the meter . 

‘-30 .00 dBm’ is the default 
setting .

Any power Level below the 
threshold will be displayed in 
purple .

Press the               button after 
selecting ‘Threshold’, you can 
set the baseline .

ENTER

Summary of Contents for CO-OPM-MPO12

Page 1: ...1 5 Meter Care 4 2 0 Getting Started 5 2 1 Explanation of Operating Keys 5 2 2 Key Function 6 2 2 1 Power ON OFF 6 2 2 2 Power Meter 7 2 2 3 Scan 8 2 2 4 dB dBm Relative Absolute Measurements 8 2 2 5...

Page 2: ...nnector MPO Angled unpinned Display Units dB dBm Display 2 8 TFT LCD 16 bit Color Battery Power Rechargeable Lithium Polymer 7 hr Operating Temperature 20 55 C Weight 13 oz Dimensions h w d 7 x 3 25 x...

Page 3: ...e scanned and power levels are displayed dB dBm Toggle between dB and dBm UOM Move UP in a menu page up in result screen Graph Power levels of all fibers are displayed as a graph Recall Recall saved m...

Page 4: ...If Manual is selected the user selects the fiber to be measured Press the button mode will change between Auto and Manual and vice versa You can select the different fibers using Press the button to...

Page 5: ...res the power measurements A scan will appear with dB values close to 0 00 dB A graph is also available Remove test jumper and replace with jumper to be measured Press scan The relative loss of the ju...

Page 6: ...s the user to save a measurement The following message shows and the measurement is saved using the current date and time as the filename Then press the button to save To abort saving press ESC ENTER...

Page 7: ...ged with the and buttons after offset value is entered 5 jkl 8 tuv 2 3 1 Polarity Use this option to change the polarity of the measurement Straight Type A Rollover Type B Flipped Type C 2 3 3 Auto Po...

Page 8: ...he data you want to delete the message appears on the screen to confirm to delete or not Press the button to delete measurement from the memory ENTER ENTER ENTER 5 jkl 8 tuv 2 3 6 Data Format You can...

Page 9: ...s If you choose Measured only active fibers will be displayed 5 jkl 8 tuv 2 3 8 Scan type This option allows the user to choose the scan type Press Scan Single or Real Time using the and keys user can...