SECTION 5
PROPANE GAS SYSTEM
5-4
Class A
safety valves which relieve excessive
pressure by discharging gas to the
atmosphere.
•
Never use an open flame to test for propane
gas leaks. Replace all protective covers and
caps on propane system after filling. Make
sure valve is closed and door latched securely.
•
Portable fuel-burning equipment, including
wood and charcoal grills and stoves, shall not
be used inside the recreational vehicle. The
use of this equipment inside the recreational
vehicle may cause fires or asphyxiation.
•
Regulators are equipped with a protective
cover. Make sure that the regulator vent faces
downward and that the cover is kept in place
to minimize vent blockage which could result
in excessive gas pressure causing fire or
explosion.
PRESSURE REGULATOR
The pressure regulator is protected from the
elements by a plastic cover which should be left
in place at all times. Only your dealer or a
qualified propane gas service should remove the
regulator cover for adjustments.
Regulator Freeze-up
Regulator freeze-ups are caused by the
presence of moisture in fuel. This moisture will
pass through the cylinder valve and into the
regulator where it can freeze.
Fuel producers, tank and bottle manufacturers
and propane gas dealers take every precaution to
reduce moisture, but sometimes only a fraction of
an ounce of moisture entering the tank can cause
problems.
WARNING
Visually inspect the pressure regulator
vent periodically for blockage by
accumulated debris or insect nests, etc.
Vent obstruction could result in excessive
pressure which could cause a fire or
explosion.
If any obstruction is apparent, have the
regulator serviced by your dealer or a
qualified propane gas service center.