User's manual
11
MENU 9 - Hybrid System
ECO/COMFORT Heating operating mode
To select the Hybrid System's operating mode on the basis of energy
saving and comfort, proceed as follows:
- press the M
ENU
/OK key, and
key, and
000
fl ashes on the display
fl ashes on the display
- turn the encoder to select the menu
900
- "Hybrid System
Parameter"
- press the M
ENU
/OK key to access submenu
key to access submenu
900
- "User parameters"
- press the M
ENU
/OK key and turn the encoder to access parameter
900
- "ECO/COMFORT Heating operating mode"
- press the M
ENU
/OK key to change the parameter, turn the encoder
to select the operating mode
- press the M
ENU
/OK key to store the modifi cation
- press the E
SC
key to exit the menu.
This setting can be made by pressing and holding key
6
, the Heating
operating mode key on the TALIA GREEN HYBRID for 5 seconds.
Boiler/Heat pump Manual-Forced
If one the two appliances is faulty or operating incorrectly, it is
possible to deactivate it and use the other device to meet all heating
requirements.
Proceed as follows:
- press the M
ENU
/OK key, and
key, and
000
fl ashes on the display
fl ashes on the display
- turn the encoder to select the menu
900
- "Hybrid System
Parameter"
- press
the
M
ENU
/OK key to access submenu
key to access submenu
900
- "User parameters"
- press the M
ENU
/OK key and turn the encoder to access parameter
901
- "Boiler/Heat pump Manual-Forced function"
- press the M
ENU
/OK key to change the parameter, turn the encoder
to select the appliance
- press the M
ENU
/OK key to store the modifi cation
- press the E
SC
key to exit the menu.
This setting can be made by pressing and holding key
4
, the Mode
key, for 5 seconds and turning the encoder.
Following an intervention by a qualifi ed technician, the value of
parameter 901 must be reset to 0 - Auto.
Otherwise, the boiler or heat pump will be permanently excluded.
menu
sub
-menu
par
ameter description
"Note on display"
value
default
settings
9
HYBRID SYSTEM PARAMETER
9
0
USER PARAMETERS
9
0
0
Operating mode
ECO/COMFORT Heating
0 = ECO PLUS
1 = ECO
2 = MODERATE
3 = COMFORT
4 = COMFORT
PLUS
2
The hybrid operating mode can be selected on the basis of
energy saving and comfort.
ECO PLUS - most economical operation
up to COMFORT PLUS, the most comfortable.
This setting can be made by pressing and holding key
6
, the
Heating hybrid operating mode key
, for 5 seconds
9
0
1
Boiler/Heat pump Manual-
Forced
0 = Auto
(System active)
1 = Boiler
only
2 = Heat pump
only
0
This parameter enables the hybrid to operate automatically
or in boiler only or heat pump only mode
This setting can be made by pressing and holding key
4
, the
Mode key
, for 5 seconds and turning the encoder.