2

SPECIFICATIONS

INSTALLATION REQUIREMENTS

Model VFP500-N 
Gas type 

NG 

Operating pressure 

2,1kPa 

Min Regulator size to comply with SANS 1237 

N/A 

Max. gas consumption 

N/A 

Max. mJ input 

N/A 

Max. kW input 

3.6 kW/h 

Gas inlet connection 

Ø8mm compression 

Ignition 

Piezo Spark 

Oxygen depletion system ( Pilot )  

ODS min 18.5% O2 

Min Room size without permanent ventilation 

35 m³ 

 

 

Your VFP500-N Fireplace is designed to be 

hung on the wall

.

Choosing a site:

 

 

This fireplace may be installed in any room in a home except in bedrooms or 

 

bathrooms where the humidity levels are too high. (See page 1)

 

Avoid areas where there are strong draughts

, which may be generated by  

 

outside doors. It is recommend that the fireplace 

should not

 be installed  

 

within 500mm of any air vent, as this could affect the working of the ODS. 

Clearances to combustible materials:

 

 

Combustible materials are defined as wood, fabrics, or other materials likely  

 

to burn when exposed to flame. Any other material which is likely to discolour,  

 

melt, or lose shape when exposed to moderate heat, should fall into the  

 

same category.

Min clearance to the sides 

100 mm

Min clearance to the sides for curtains & fabric 

500 mm

Min clearance to the ceiling 

800 mm 

Min clearance to a floor ( including carpet ) 

100 mm

Min clearance to combustible furniture in front  

1000mm

 

A masonry shelf may be fitted 500mm above the fireplace

 but under no  

 

circumstances  should any electrical equipment such as plasma screen  

 

TV sets be positioned on the wall above. Any ornaments positioned above  

 

the fireplace must be able to withstand the elevated temperatures and  

 

moisture. No combustible materials whatsoever must be used or placed  

 

above the fireplace.   

Summary of Contents for VFP 500-N

Page 1: ...ating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference NATURAL GAS VFP 500 N These appliances conform to the requirements of SAN...

Page 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family...

Page 3: ...ATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6...

Page 4: ...ns It is the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered Natural Gas installer and must comply with the insta...

Page 5: ...of any air vent as this could affect the working of the ODS Clearances to combustible materials Combustible materials are defined as wood fabrics or other materials likely to burn when exposed to flam...

Page 6: ...jet and ensure the burner is seated correctly 2 Fill the burner with the special black radiant ceramic ash or glass chips 3 Spread the decorative stone or ceramic evenly around the burner 4 No large...

Page 7: ...hed during use wait 3 minutes before repeating the ignition procedure 5 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 6 Select the r...

Page 8: ...See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensure that there is adequate ventilation See Page 1 Do not tamper with jets burners or regulator settings N...

Page 9: ...WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the...

Page 10: ...rs are the biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a problem in the home have your fireplace serviced...

Page 11: ...r This does not mean that it is rust proof it will require regular maintenance to preserve this protective surface layer in order to enjoy the high quality standard that is to be expected from Chad O...

Page 12: ...Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email Sales chad o chef co za www chad o chef co za...

Reviews: