background image

2

SPECIFICATIONS

INSTALLATION REQUIREMENTS

Model VFDS1000 
Gas type 

LPG 

Operating pressure 

2,8kPa 

Min Regulator size to comply with SANS 1237 

2 kg/hr 

Max. gas consumption 

0.75 kg/hr 

Max. mJ input 

37.5 mJ/hr 

Max. kW input 

10.6 kW/h 

Gas inlet connection 

Ø8mm compression 

Ignition 

Piezo Spark 

Oxygen depletion system ( Pilot )  

ODS min 18.5% O2 

Coals 22 
Pebbles 18 
Min Room size without permanent ventilation 

101 m³ 

Choosing a site:

 

 

This fireplace may be installed in any room in a home except in bedrooms or 

 

bathrooms where the humidity levels are too high. (See page 1)

 

Avoid areas where there are strong draughts

, which may be generated by  

 

outside doors. It is recommend that the fireplace 

should not

 be installed  

 

within 500mm of any air vent, as this could affect the working of the ODS. 

Clearances to combustible materials:

 

 

Combustible materials are defined as wood, fabrics, or other materials likely  

 

to burn when exposed to flame. Any other material which is likely to discolour,  

 

melt, or lose shape when exposed to moderate heat, should fall into the  

 

same category.

Min clearance to the sides 

100 mm

Min clearance to the sides for curtains & fabric 

500 mm

Min clearance to the ceiling 

800 mm 

Min clearance to a floor ( including carpet ) 

100 mm

Min clearance to combustible furniture in front  

1000mm

 

A masonry shelf may be fitted 500mm above the fireplace

 but under no  

 

circumstances  should any electrical equipment such as plasma screen  

 

TV sets be positioned on the wall above. Any ornaments positioned above  

 

the fireplace must be able to withstand the elevated temperatures and  

 

moisture. No combustible materials whatsoever must be used or placed  

 

above the fireplace.   

Summary of Contents for VFDS 1000

Page 1: ...perating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference LP GAS VFDS 1000 These appliances conform to the requirements of SANS 1539 2017 LPGSA Permit Number 1013 44 1 RSA 12 A ...

Page 2: ... S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family ...

Page 3: ...LATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6 Cleaning 7 Servicing 7 Guarantee Claim Form 8 Table of Contents ...

Page 4: ...lations It is the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered LP Gas installer and must comply with the installation requirements of SANS 10087 1 Ask to be shown the installer s card with his registration number before allowing the installation work to commence and make a note of his QCC number Upon completi...

Page 5: ...ir vent as this could affect the working of the ODS Clearances to combustible materials Combustible materials are defined as wood fabrics or other materials likely to burn when exposed to flame Any other material which is likely to discolour melt or lose shape when exposed to moderate heat should fall into the same category Min clearance to the sides 100 mm Min clearance to the sides for curtains ...

Page 6: ... burner with the special black radiant ceramic ash or glass chips 3 Spread the decorative stone or ceramic evenly around the burner 4 Place the pebbles or coals in a single layer double row spread across the burner allowing about 10mm gaps between them 5 Use only the number of pebbles or coals supplied Testing and Commissioning Turn on the gas supply and test for leaks with soapy water Ensure that...

Page 7: ...shed during use wait 3 minutes before repeating the ignition procedure 5 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 6 Select the required HIGH or LOW setting 7 To turn the fire OFF depress the knob and turn it clockwise to the OFF position and release This will extinguish both the main burner and the pilot burner iNlET prEssurE...

Page 8: ...recommended with a 10mm gap between them DO NOT use more coals or pebbles than recommended and supplied See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensure that there is adequate ventilation See Page 1 Do not tamper with jets burners or regulator settings NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT CHAD O CHEF products are pres...

Page 9: ...s WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the heater may not be working properly Get fresh air at once Have the heater serviced Some people are more affected by carbon monoxide than others these include pregnant women people with heart or lung d...

Page 10: ...the biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a problem in the home have your fireplace serviced just before the new season begins Suggested procedure for servicing 1 Isolate the gas supply and work on a cold unit 2 Remove the coals or pebbles 3 Remove the burner and empty the black radiant ceramic ash ...

Page 11: ...er This does not mean that it is rust proof it will require regular maintenance to preserve this protective surface layer in order to enjoy the high quality standard that is to be expected from Chad O Chef Read your complete Instruction manual ensure that you understand it fully If you have any concerns please contact our service department for clarity Product Name ________________________________...

Page 12: ...Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email Sales chad o chef co za www chad o chef co za Version 01 ...