background image

6

INSTALLATION INSTRUCTIONS

 

To clean the Braai Grids remove from the appliance and soak in hot 
detergent solution or place in the dishwasher. Braai Grids may be cleaned 
with ”Scotch Brite” scouring pads. Rinse well in clean water before placing 
the parts back into the appliance.

 

Avoid contact with aggressive chemicals.

 

Don’t use oven cleaners.

 

Don’t store any chemicals (especially pool chemicals) close to your braai.

 

This appliance requires a shut-off valve to be fitted in a convenient position 
for the customer.

 

This appliance requires a minimum of 1m copper pipe to be fitted directly 
onto the compression fitting located at the gas inlet.

 

This appliance requires an operating pressure of 2,8 kPa for LP Gas and 2.1 
kPa for Natural Gas. A suitable regulator that complies with the requirements 
of SANS 1237 must be installed outside. Ensure that the flow capacity of the 
installed regulator is sufficient to drive the model to be installed.

 

It is preferable that the Sizzler Grill be installed in the open and any surrounds 
are of a non-flammable material.  If installed in a structure that can be 
damaged with heat, ensure that a suitable flame retardant buffering is 
used. The manufacturer will not accept any responsibility if the installation 
instructions re safety clearances are not adhered to.

 

Where a flue or fume extraction device is deemed to be required, contact 
the manufacturer for information on these products. Where the appliance is 
installed inside then it is recommended that such a device be fitted prior to 
commissioning the appliance and handing it over to the user.

 

Before lighting the appliance for the first time ensure that there are no gas 
leaks and that a pressure test is done.

 

The Gas installer is required to light the burners in the presence of the 
owner/ user and to instruct that person in the safe operation of the appliance 
and the complete installation.

 

It is particularly important to show the user the position of the  isolator  valve

 

Installers are required to provide the owner/user with a completion 
certificate which must be dated and signed by both parties. Ensure that your 
name and SAQCC number appear on the certificate. 

SERVICING

Your local dealer will gladly handle any concern that you have and will take the 
appropriate action. Spares are readily available countrywide.

Summary of Contents for SGG320

Page 1: ...N 620 N SIZZLER GAS BRAAI INSTALLATION OPERATING INSTRUCTION MANUAL Please read these instructions carefully before installation use and retain them for future reference These appliances conform to th...

Page 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF BRAAI a n d W E L C O M E t o t h e CHAD O CHEF family...

Page 3: ...mation 2 Preparing the CHAD O CHEF Gas Grill for use 3 Lighting the appliance 4 Using The Appliance 5 Turning Off the Appliance 5 Ventilation requirements 5 Care Maintenance 5 Installation Instruction...

Page 4: ...installation the installer is required to explain the operational details of the appliance together with the safety instructions You will be asked to sign acceptance of the installation and be provide...

Page 5: ...as smell close the control valve on the appliance Make sure that there are no naked flames within 5 metres of the appliance and check for leaks as described below Never check for gas leaks with a nake...

Page 6: ...ult in poor performance and may damage the appliance The use of Rocks from other suppliers may result in poor performance and the manufacturer accepts no responsibility if other rocks are used Ensure...

Page 7: ...and turn far LH control knob counter clockwise to ON position 3 Push ignitor button repeatedly 4 Check that pilot burner ignites 5 If not alight turn gas off and wait for 30sec 6 Turn far LH control k...

Page 8: ...CHEF appliances are made from stainless steel Whilst this is a very durable material and is widely used for appliance manufacture its surface can be damaged by misuse or the application of unsuitable...

Page 9: ...If installed in a structure that can be damaged with heat ensure that a suitable flame retardant buffering is used The manufacturer will not accept any responsibility if the installation instructions...

Page 10: ...7...

Page 11: ...his protective surface layer Customers staying in areas or homes with higher atmospheric corrosion will be expected to purchase the coastal grade stainless steel option along with regular maintenance...

Page 12: ...9 Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email sales chad o chef co za www chad o chef co za...