6
INSTALLATION INSTRUCTIONS
•
To clean the braai Grids remove from the appliance and soak in hot
detergent solution or place in the dishwasher. braai Grids may be cleaned
with ”Scotch brite” scouring pads. Rinse well in clean water before placing
the parts back into the appliance.
•
Avoid contact with aggressive chemicals.
•
Don’t Use oven cleaners.
•
Don’t store any chemicals (especially pool chemicals) close to your braai.
NB: In order to function correctly the unit needs adequate ventilation holes to
be cut into the masonry construction housing the unit e.g. (2x 100mm holes)
•
This appliance requires a shut-off valve to be fitted in a convenient position for
the customer.
•
This appliance requires a minimum of 1m copper pipe to be fitted directly onto
the compression fitting located at the gas inlet.
•
This appliance requires an operating pressure of 2,8 kPa for LP Gas and 2.1 kPa
for Natural Gas. A suitable regulator that complies with the requirements of SANS
1237 must be installed outside. Ensure that the flow capacity of the installed
regulator is sufficient to drive the model to be installed.
•
It is preferable that the Hob Grill be installed in the open and any surrounds are
of a non-flammable material. Where the appliance is placed in a surround of
wood or other flammable material, ensure that the side and rear clearances
indicated in Figs 1, 2 & 3 are followed as applicable. The manufacturers will not
accept any responsibility if the installation instructions re safety clearances are
not adhered to.
•
Provision must be made for the drip tray to be removed.
•
Where a flue or fume extraction device is deemed to be required, contact
the manufacturer for information on these products. Where the appliance is
installed inside then it is recommended that such a device be fitted prior to
commissioning the appliance and handing it over to the user.
•
before lighting the appliance for the first time ensure that there are no gas leaks
and that a pressure test is done.
•
The Gas installer is required to light the burners in the presence of the owner/
user and to instruct that person in the safe operation of the appliance and the
complete installation.
•
It is particularly important to show the user the position of the isolator valve
•
Installers are required to provide the owner/user with a completion certificate
which must be dated and signed by both parties. Ensure that your name and
SAQCC number appear on the certificate.
SERVICING
Your local dealer will gladly handle any concern that you have and will take the
appropriate action. Spares are readily available countrywide.
Summary of Contents for HGG 330