background image

1.1 Connect the ED-SH-03 module to a luminaire

1. Install the module

Connect the module to the luminaire by placing the Neutral câble (blue) in the N terminal, 
the phase (brown) in the terminal (O2). Connect the module to the power supply by placing 
the neutral (blue) câble in the N terminal, the (brown) phase in the terminal (L). Connect then 
the second terminal (L) to the connector (O1). 

Mini module lighting,  dry contact and  pulse

ED-SH-03

EN

1.2 Connect the module to a push button or  a classic switch  

5. Technical characteristics

2. Associate with a Edisio command

3. Clear the link with a Edisio command

4. Advanced modes

1x

1.3. Connect the module to a gate or a electric lock

1x ED-SH-03

!! Warning !!
Turn off the power before handling.
If in doubt about your installation, please consult your electrician.

L

O

2

S

O

1

N

L

       L N

230V~50Hz

Connect the module to the power supply  in
placing the Neutral câble (blue) in the
terminal N, the phase (brown)
in the terminal (L).
Connect your gate to the terminal O1 and O2
To put your module in pulse mode, press the 
R button 8 times. Press again 8x on the R 
button to return to On / Off mode.
By default, the module is configured in 0.5 second 
pulse, if you want a 4 second pulse, press the R button 3x.
Press the R button 3x again to return in 0.5 pulse mode

Protocol: edisio
Frequency: 868.3MHz
Max Power: 3 mW EIRP
Transmission range: 150m (in free field)
Max. 32 associated transmitters
Operating temperature: -5 to 50 ° C
Power supply: 230V ~ 50Hz
Max .: - 8.5A (cos φ = 1)
            - resistive load: 2000W
            - LC loads (LED): 500W (Max 10 bulbs)
h x w x d: 40x40x20mm

ED-SH-03

By default or after reset, the timer and the repeater are deactivated and the module is in 

light mode

Reset:

To reset the module to factory mode, press the R button for 10 seconds.
The led flashes quickly to confirm.

Timer

 :

It is possible to activate a timer on the module so the connected device automatically 
turns off after the time limit. Several timers are possible:
2 minutes : Activate: 3xR => the led flashes 3x slowly to confirm.
                       Disable: 3xR => the led flashes 3x quickly to confirm.
5 minutes: same as 4xR / 10 minutes: same as 5xR / 30 minutes: same as 6xR / disabled by 
default

6. Supplementing your installation

Supplement your installation with Edisio solutions to control your heating, lighting, roller
shutters or garden. Easy, high-quality, scalable and economical...learn about all of the
Edisio solutions at www.chacon.com 

CHACON declares that the ED-SH-03 complies with the essential requirements and other relevant provisions of the
RED 2014/53 / EU Directive. The complete text of the EU declaration of conformity is available at the following
Internet address: www.chacon.be/en/conformity 

www.chacon.com /conformity

Recycling
In accordance with the European WEEE (2002/96 / EC) and Battery Directive (2006/66 / EC), all electrical, 
electronic or accumulator devices must be collected separately by a local and specialized waste collection 
system. Do not dispose of these products with ordinary garbage. Consult the regulations in force. The 
garbage mark indicates that this product should not be disposed of with household waste in any EU 
country. To prevent any risk to the environment or human health from uncontrolled disposal, recycle the 
product responsibly to promote the sustainable use of material resources. To return your used device, use 
the return and collection systems or contact the original dealer. He will carry out the recycling in the 
respect of the regulatory provisions.

Indoor use (IP20), do not use in a humid environment.

Press the R button on the Edisio module once.

Within 10 seconds, press the switch button.

Within 10 seconds, press the R button on the module again.

Press the R button on the Edisio module for 5 seconds.

Within 10 seconds, press the key to be erased from the switch.

Within 10 seconds, press the R button on the module again.

2 x

2 x

1 x

E

By default, the module is configured
for a classic or a toggle switch, if you have
push switch, press 9x on the R button 
of the module.

Press the R button again 9x
to return to the classic button mode. 
   

Connect your push button or switch to 
the terminal L and at the terminal S

Signal repeater (meshing):
To extend the radio range between your devices, you can enable this function.
By default, the function is disabled in order to optimize the response time of the module.
Activate: 7xR => the led flashes 7x slowly to confirm.
Disable: 7xR => the led flashes 7x quickly to confirm.
Do not activate more than 5 "meshing" receivers per installation.

Remove the R button:
If you have difficulty accessing the module after installation we advise you to
shift the R button to the E button of a edisio switch.
Activate: 2xR => Press button E of the switch => the led flashes 2x to confirm.
The switch becomes Master. You can now pair other remote controls

L

O

2

S

O

1

N

L

       L N

230V~50Hz

L

O

2

S

O

1

N

L

       L N

230V~50Hz

R button

Support

V6.1 200311

www.chacon.com/support

For indoor use
only

Alternating
current

Reviews: