background image

AEROF

AN I&M-1

104

5.

Mount the housing using the screws in the joists and then
secure them tightly. Make all the electrical connections in the
electrical box, per the wiring diagram, and attach the electrical
box cover. Attach the discharge duct tightly onto the fan outlet.

Note: In order for the fan to operate efficiently, keep the
discharge duct as straight as possible.
6.

To complete the installation, install the lamps (if applicable)
and mount the grille.

MODEL

VOLTAGE

(V)

FREQUENCY

(HZ)

POWER CONSUMPTION (W)

MOTOR

PL LAMP NIGHT LIGHT

TBF90

120

60

25

--

--

TBF120

120

60

40

--

--

TBFS90L

120

60

25

26

4

TBFS120L

120

60

40

26

4

TBFR90L

120

60

25

26

4

TBFR120L

120

60

40

26

4

FAN SPECIFICATIONS

R

RE

EC

CO

OM

MM

ME

EN

ND

DE

ED

D  M

MA

AIIN

NT

TE

EN

NA

AN

NC

CE

E

1.

Turn the power off and lock it out prior to servicing or cleaning.

2.

To clean the grille, first remove it from the fan then use a
soft brush and clean water to remove the dirt. If the dirt is
not easily removed, wash with a neutral detergent.

3.

In order to remove the impeller and housing for maintenance,
first remove the light, night light and reflector (if applicable).
Then unplug the electrical connection and remove the 4
screws that secure the fan assembly to the housing. To
clean the impeller and housing, remove the motor and then
wash with water or a neutral detergent, as required.

Note: Keep all electrical components away from water. Do not
use corrosive chemicals or water in excess of 60C (140F) to
clean plastic parts.

W

WIIR

RIIN

NG

G  P

PR

RO

OC

CE

ED

DU

UR

RE

E

Refer to the wiring diagrams below.

www.continentalf

www.continentalfan.com

an.com

 

USA - Continental Fan Manufacturing Inc.

USA - Continental Fan Manufacturing Inc.

203 Eggert Road, Buffalo, NY  14215
T: 716-842-0670 • 800-779-4021 • F: 716-842-0611

Canada - Continental Fan Canada Inc.

Canada - Continental Fan Canada Inc.

12-205 Matheson Blvd E, Mississauga, ON  L4Z 3E3
T: 905-890-6192 • 800-779-4021 • F: 905-890-6193

better

 AIRFLOW 

by

 DESIGN

TM

FAN ONLY (MODELS TBF90, TBF120)

FAN/LIGHT COMBINATION (MODELS TBFR90L, TBFS90L, TBFR120L, TBFS120L)

FAN

MOTOR

RED

GREY

WHITE
GREEN / 

YELLOW

CAPACITOR

LIGHT

COMMON

FAN

HIGH

COMMON

LOW

NIGHT LIGHT

TO NIGHT LIGHT BY OTHERS

TO BATHROOM LIGHT BY OTHERS

SPEED CONTROL SWITCH

LEVITON 3 WAY SWITCH

OR EQUAL

BLACK

WHITE

GROUND

117 V

POWER

SUPPLY

EXHAUST FAN

MODEL TBF90 & TBF120

3 CIRCUIT CONTROL SWITCH 

LEVITON COMBINATION SWITCH 

OR EQUAL

RED

GREY

WHITE
GREEN / 

YELLOW

CAPACITOR

EXHAUST FAN

MODEL TBF90 & TBF120

HOT

GROUND

NEUTRAL

115V POWER

SUPPLY

OFF

LOW

HIGH

SWITCH BY OTHERS

NOTE:   

MULTIPLE SINGLE POLE SWITCHES MUST NOT BE USED; FAN MOTOR FAILURE WILL OCCUR. 

 

REQUIRES THE USE OF ONE THREE POSITION SWITCH FOR OFF, HIGH AND LOW SPEED.

FAN

MOTOR