TROUBLESHOOTING
Only qualified personnel should work on electrical equipment. Working on or
near energized equipment could result in death or serious injury.
1. If the fan fails to start, consult wiring diagram to ensure proper connection.
2. Check the incoming supply for proper voltage.
3. Ensure that the electrical service to the fan is locked in the “OFF” position.
4. Use a meter to test for continuity across the fan motor leads.
5. If the motor leads show continuity, rewire the fan and timer.
6. Turn on the electrical supply and restart. If fan fails to start, remove the timer from the circuit.
7. Connect the incoming power supply directly to the fan motor. Turn on power to fan.
8. If fan fails to start, please contact factory.
RECOMMENDED MAINTENANCE
Disconnect and lock out power supply before performing any maintenance.
Working on or near energized equipment could result in death or serious injury.
1. Fan bearings are sealed. No additional lubrication is necessary.
2. Periodic inspection, based upon usage, should be performed to ensure that the fan impeller is
not obstructed. The fan should be inspected a minimum of every six (6) months.
3. Excessive fan noise or vibration may indicate an obstructed impeller.
4. To inspect and clean impeller:
a) Remove the duct from the fan inlet and remove any obstruction from the impeller.
b) Reconnect the duct to the fan.
c) Turn power supply on.
WIRING DIAGRAM
WARNING
WARNING
NOTE: JUMPER MUST BE USED WHEN
MOTOR IS OPERATED WITH FAN TIMER
GREEN
WHITE
BLACK
CAPACITOR
B
LA
CK
W
H
IT
E
G
R
EE
N
B
R
O
W
N
B
LA
CK
B
LU
E
YE
LL
O
W
FAN
MOTOR
117 VOLT SUPPLY
FROM FUSE PANEL
WHITE JUMPER
FAN TIMER
OFF
TERMINAL
BLOCK
DVK-T-I&M-1603
1-800-779-4021 • www.continentalfan.com
Continental Fan Manufacturing Inc.
203 Eggert Road
Buffalo, New York 14215
Continental Fan Manufacturing Inc.
6274 Executive Blvd.
Dayton, Ohio 45424
Continental Fan Canada Inc.
12-205 Matheson Blvd E
Mississauga, Ontario L4Z 3E3