Fuse
1,25 AT
Engine
protection switch
Control lamp
Device
button
24 V Power
supply for the
engine part
ENGLISH
11. Fault and error search
When errors occur, the followings point should be observed
1- No function after the connection of the device: NG-3 and NG-4
The automatic security could be interstratis
fi
ed. Please disconnect the appliance
switch and try it again after 5 minutes.
Please control the fuse which is on the appliance switch. When the fuse is defect,
exchange it for a new 1,25 At fuse.
1.1- NG5 fault repair
a) Your cutting device can break down because of overheating. Please let your
machine cool down for 5 minutes and try again. When the cutting device doesn’t
function, a specialist or expert must exchange the 0.8 A lock.
3.- Noises in the head part
• Check out whether the blade is attached rightfully (the smooth surface should be
visible from above).
• Screw the cover bolts tightly, so that they aren’t loose-
fi
tting.
• If there are still noises, contact the Devran, Saran or Seymen merchant or the
producer company Ceylan.
2. Fuse replacement
1
2
NG 3 ve NG 4
NG-5
The 0.8 A lock is
located under the
cover/cap and
must be repaired
or exchanged by a
specialist.
The 0.8 A cock is under the
cover.
The On/Off button