Page 1: ...2018 06 01 Installation and maintenance instructions AquaTank stainless steel ...
Page 2: ......
Page 3: ...e chlorine 5 1 7 Warranty 5 2 Installation 6 2 1 Siting 6 2 1 1 Space required 6 2 1 2 Substrate foundation load bearing capacity 6 2 2 Connection 6 2 2 1 Electrical connection 6 3 Commissioning Operation 7 3 1 Maintenance 7 4 Design data 8 4 1 Ratings 8 4 2 Material 8 4 3 Insulation characteristics 8 5 Dimensions and technical data 9 5 1 AQATANK 316 Ti 9 5 2 AQUATANK 316 HC Ti 10 6 Tap water heat...
Page 4: ...om misuse The operator bears the risk Please keep the order data article numbers of the AquaTank handy so that we can deal with your needs and spares orders promptly Safety information The AquaTank must be connected according to the common regulations and standards of your country Each hot water storage system or storage vessel has to be equipped with safety devices Controls and instruments or saf...
Page 5: ...at are the main cause of water hardness The temporary component of water hardness carbonate hardness is the part that is precipitated as boiler scale when the water is heated and is deposited on the surfaces of that water storage systems increasing with increasing temperature and according to the lime carbon dioxide balance of the water Water with high lime content total hardness of 2 5 3 8 mmol 1...
Page 6: ...connection and the equipment 2 1 1 Space required Install the AquaTank in a room that is protected from frost flooding and is adequately ventilated The maximum admissible temperature in the room where the system is installed must not exceed 40 C Make sure that there is a adequate space between the AquaTank and the wall and other components to allow maintenance and inspection minimum 60 cm 2 1 2 Su...
Page 7: ...ybe necessary after the unit has been first pressurerised The periodical change of cold and hot temperatures causes a load alteration on all gaskets and sealings and degrades its elasticity during the period of operation This can cause leaks after a certain period Call the attention of the user operator regarding this circumstance Give the necessary instructions for periodical checks of all water ...
Page 8: ...ED classification The DECLARATION of SUPPLIER is directly attached to the delivered vessel Energy efficiency class according to European Union rule N 814 2013 and N 812 2013 4 2 Material AquaTank 316Ti The vessel and connections are made of AISI 316Ti according to DIN material number 1 4571 BS 320 S 21 AFNOR Z 6 CNDT 17 12 SS 2350 4 3 Insulation characteristics Eurofire class D S1 do EN 13501 1 or...
Page 9: ...l AQUATANK 316Ti 316 Ti HC Installation and maintenance instructions 9 5 Dimensions and technical data 5 1 AQATANK 316 Ti Energy efficiency class according to European Union rule No 814 2013 and No 812 2013 ...
Page 10: ...CM737 Consignes d exploitation 10 5 2 AQUATANK 316 HC Ti Energy efficiency class according to European Union rule No 814 2013 and No 812 2013 ...
Page 11: ...Manual AQUATANK 316Ti 316 Ti HC Installation and maintenance instructions 11 6 Tap water heating capacity 6 1 Characteristics ...
Page 12: ...etetherm The results of the assessment can only state whether or not the terms of the warranty apply 7 1 Exclusion factors Non compliance with the guidelines for installation configuration and maintenance Over pressures water hammer scaling noncompliant water quality Also excluded from the warranty Fitting costs refitting costs packaging transport and any accessories or equipment not manufactured ...
Page 13: ... DESIGNATION REP DESIGNATION A B VR Primary inlet Primary Outlet Setting valve HE PP PC Heat Exchanger PHE Primary pump single double Charging Pump 1 or 2 CW Cold water inlet PR Recycling pump on installation V3V Mixying 3 port control valve with actuator V Manual gate valve PRV Pressure relief valve S1 DHW temperature sensor master ...
Page 14: ... 14 9 Neodul Installation 1 Put fleece plugs into drilled holes 2 Connect insulation segments together and close hooking closure step by step 3 Push in left part of hooking closure Right part slips over left part of hooking closure ...
Page 15: ...Manual AQUATANK 316Ti 316 Ti HC Installation and maintenance instructions 15 4 Insert top insulation after mounting insulation segments ...
Page 16: ...CM737 Consignes d exploitation 16 5 Insert inspection hole protection ...
Page 17: ...Manual AQUATANK 316Ti 316 Ti HC Installation and maintenance instructions 17 10 Connections 10 1 AQT316Ti 10 2 AQT316 TiHC ...
Page 18: ...Cetetherm sas ZI du Moulin Route du Stade 69490 Pontcharra sur Turdine France www cetetherm com ...