SM-PFP-25hp-DSL-MR

INSTRUCTIONS  MANUAL

DOS AND DONTS

Do…

• Read your Kubota D902 owner’s manual
• Close your drain valve on the pump casing before starting the engine 
• Seal up any air that could leak into the suction side
• Charge you battery at least once every three months 
• Stop your pump before fuelling 

Do Not…

• Let your pump freeze up with water in it (drain the casing)
• Allow sand in the suction it will damage the wear ring and the mechanical seal (use floating strainer if water supply doubtful)
• Run your pump dry for more than 2 minutes at idle (prime as soon as possible)
• Use your pump with less than 12 in of water below the inlet of the suction hose
• Allow your pump to run without surveillance 
• Run the pump with the discharge valve closed for more than 1 minute

STARTING PROCEDURE

• Place your pump on a hard, stable surface within 15° from horizontal.
• Check the oil and the fuel tank level.
• Connect your suction hose. Make sure that there is a rubber seal on the adapter and screw it tight.
• Close all the discharge valves.
• Close the drain valve (below the casing of the pump).
• Turn key to ON position. The “glow plugs” light comes on indicating glow plugs are preheating combustion chamber.
• Start the engine and let it idle.
• When “glow plugs” light goes out, turn key to “Ignition” (IG).
• Open the primer ball valve. 
• Close this ball valve only when you have pressure on the suction.
• Push the priming button. 
• When water comes out of the priming pump (it should take approximately 10 to 15 sec. with a 10 ft x 4¨ suction hose), release the

electric priming button.  Do not operate the primer more than 20 sec.

• Open the discharge valve to allow water to run through the pump
• Adjust the RPM with the throttle to desired pressure.

N.B. 1

The exhaust system is very hot. Do not touch 

N.B. 2

When you are done with the pump, always drain the pump casing