19. Unsnap the PCR saddles from the housing on the PCR assembly, carefully prying them

from the bottom using a small flat bit screwdriver

20. Remove the PCR and the PCR cleaning roller, then remove the saddles

21. Clean the PCR contact with a cotton swab, then apply a small amount of conductive

grease on it

22. Clean the black conductive saddle with a cotton swab, then apply a small amount of

conductive grease into it.

Apply conductive grease

here

23. Take out the new CET PCR and PCR cleaning roller and remove the protective sleeve from

the PCR.

Wear clean disposable gloves or do not touch the PCR working surface with bare hands

24. Reinstall the saddles and the gear onto the PCR and the PCR cleaning roller

25. Reinstall the PCR and the PCR cleaning roller into the PCR assembly holder

26. Make sure the PCR is moveable and spring loaded

27. Reinstall the PCR assembly into the drum unit and secure it with 2 screws using a PH#2

screwdriver

28. Take out the new CET OPC drum

29. Remove the protective wrap, then place the OPC drum into the drum unit

30. Align the notches on the drum unit with the corresponding tabs on the developer unit

31. Carefully connect the drum unit and the developer unit sections together

32. Reinstall the front OPC drum support hub and secure it with two screws using a PH#2

screwdriver

33. Arrange the toner sensor cable in the drum unit section plastic housing, then connect the

connector

34. Reinstall the rear OPC drum support hub and secure it with three screws using a PH#2

screwdriver

35. Reinstall the rear PCDU cover and secure it with one screw using a PH#2 screwdriver

36. For correct operation of the rebuilt drum unit, reset the corresponding PM counters by

SP3-701 or by selecting [PM Counter / New Unit Set] from the menu

37. To find the components used in this video please visit our web site www.cetgroupco.com