background image

 Instruction Handbook                              PFP-20hpKHL-MR  

- 22 -

 

 

C.E.T. Fire Pumps Mfg. This handbook is subject to change without notice, 

Contact your local C.E.T. dealer or C.E.T. direct to ensure you have the latest version.

 

 

12.

 

 

General Warranty 

 
C.E.T. FIRE PUMPS MFG. warrants to the original purchaser that C.E.T. FIRE PUMPS MFG. will, 
at its election, either replace or repair any part of the new equipment sold to the purchaser 
hereunder  which  has  been  given  no  abnormal  use;  and  which  has  received  proper 
maintenance; and which is determined by C.E.T. FIRE PUMPS MFG. to be defective in material 
or  workmanship;  and  which  has,  within  three  (3)  years  after  delivery  to  the  purchaser  be 
returned  at  the  purchaser's  expense,  with  transportation  charges  prepaid,  to  C.E.T.  FIRE 
PUMPS MFG. factory OR which has, within three (3) years after delivery to the purchaser, been 
pre-approved by C.E.T. FIRE PUMPS MFG. for a third-party to perform the work.  All problems 
shall be reported to C.E.T. FIRE PUMPS MFG. in writing and damaged parts shall be returned 
to C.E.T. FIRE PUMPS MFG.. 
 
 
Exclusions from warranty 
 
1.  C.E.T.  FIRE  PUMPS  MFG.  incurs  no  liability  under  this  warranty  or  otherwise  for  parts, 
accessories  or  components  not  manufactured  by  it,  but  purchased  for  assembly  into  the 
equipment,  but  C.E.T.  FIRE  PUMPS  MFG.  will  assign  to  the  Purchaser  whatever  warranty 
rights are extended by the supplier of such part, accessory or component 
 
2. C.E.T. FIRE PUMPS MFG. incurs no liability under this warranty or otherwise, for equipment 
which has been abused, altered or improperly maintained, or for equipment which has been 
returned for inspection or repair more than ten (10) days after defect complained of has been 
or should have been discovered by the Purchaser, or Equipment which is operated after the 
defect has been discovered. 
 
3. C.E.T. FIRE PUMPS MFG. incurs no liability for alteration or repairs unless the Purchaser 
first receives C.E.T. FIRE PUMPS MFG. / written consent or approval.  C.E.T. FIRE PUMPS MFG. 
will not be responsible for work or repairs made or done by others. 
 
4.  C.E.T.  FIRE  PUMPS  MFG.  incurs  no  liability  for  design  alterations,  parts,  accessories  or 
components which are not standard but are specified by the Purchaser for incorporation into 
the equipment. 
 
Interpretation 
C.E.T. FIRE PUMPS MFG. shall not be liable for transportation charges either in shipment to 
or by it and shall not be liable for loss of use, or consequential damage of any kind in 
connection with the sales, alteration, repair or replacement of any equipment or part thereof.  
Liability under this warranty is limited to replacement or repair and in any event shall not 
exceed the purchase price paid.  This warranty is not transferable by the Purchaser.  C.E.T. 
FIRE PUMPS MFG. reserves the right to make changes in design or add any improvements to 
the Equipment at any time without incurring any obligation to install or modify same on other 
equipment previously supplied. 

 

There are no other warranties, conditions or representations, expressed or implied, except 
the above. 

Summary of Contents for PFP-20HPKHL-MR

Page 1: ...r C E T direct to ensure you have the latest version Instruction Handbook Version 1 0 Model PFP 20hpKHL MR Your version of the pump the engine and their accessories may vary from the one seen on the i...

Page 2: ...C E T direct to ensure you have the latest version Table of contents 1 FOREWORD 3 2 SAFETY INSTRUCTIONS 4 3 DESCRIPTION 7 4 GENERAL INSTRUCTIONS 10 5 TRANSPORT AND STORAGE 11 6 PERFORMANCE 12 7 START...

Page 3: ...y of experience in building fire fighting equipment If you follow the directives given in this handbook your pump will be a useful ally for many years to come For your own safety and those around you...

Page 4: ...ler o NEVER run the engine without a muffler or proper exhaust system o NEVER operate the engine if the fuel tank cap is removed do not fill the tank while the engine is running If fuel is spilled mov...

Page 5: ...hot water scald and burn hazards NEVER let the pump run for more than one minute with discharge valve s completely closed When the pump is running make sure to always leave the discharge valve slightl...

Page 6: ...attached note will put at risk the security of the personnel operating near the pump The words danger warning and caution are used for levels of risk This symbol means that it is mandatory to read an...

Page 7: ...e the latest version 3 Description This portable pump is directly driven by the very high quality Kohler gasoline 20 hp engine It is equipped with an electric starter and also has a backup recoil star...

Page 8: ...sistance aluminum alloy body It also has an axial mechanical seal The pump can operate to a maximum pressure of 200 PSI 13 7bar It has been designed to work at a temperature between 5 F 15 C and 104 F...

Page 9: ...starter Install in a properly ventilated area Recommended individual protective equipments not included Firefighting grade protective gloves conforms to EN659 or equivalent Protective glasses Hearing...

Page 10: ...If you are not sure of the quality of the pumped water use a floating strainer to prevent drawing the sand or stone from bottom source The Kohler CH640 engine runs on unleaded gasoline fuel conform to...

Page 11: ...han 35 during transport especially if the engine has oil in it Storage Warning It is important to take into account the dangerous materials and components such as diesel oil and the battery Store away...

Page 12: ...rmal conditions geostatic height of 4 10 1 5m temperature de 59 F 15 C water clear of sand and debris atmospheric pressure 3280 1000m from sea level None conformance to the instructions given in this...

Page 13: ...ensure you have the latest version 7 Starting procedure 7 1 Place the pump on a flat and stable surface with an angle less than 15 Place your pump as close as possible to the water source WARNING NEVE...

Page 14: ...e the safety of your installation Warn the surrounding people before you start the pump It is important that you evaluate the trajectory of the hose to prevent incidents NOTE If you are pumping from a...

Page 15: ...tle control to its maximum speed CAUTION NEVER run the pump dry for more than one 1 minute it could damage the mechanical seal Always prime the pump as fast as possible 7 11 When water comes out of th...

Page 16: ...ensure you have the latest version 7 14 2 Control the opening of a valve or a nozzle at the end of the discharge hose By reducing the opening pressure will increase and flow will decrease WARNING NEV...

Page 17: ...ide the casing of the pump and valves The water could freeze and damage them CAUTION After each use it is important to flush the inside of your pump with fresh water This will help prevent damages and...

Page 18: ...test Functional test Connect suction hose of 2 5 diameter and a length of 10 Make sure to completely submerge the end of the suction hose at least 12 Connect a discharge hose of 1 5 diameter and not m...

Page 19: ...Dispose properly of the used oil and filters according to the local environmental regulations WARNING Never run the pump if the inlet strainer is not on or is damaged Maintenance Interval Daily First...

Page 20: ...tight Make sure to have well understood and applied the priming protocol of the pump Check for any possible air leakage in the suction hose Check the mechanical seal for leakage Faulty engine Refer to...

Page 21: ...posits or dust is obstructing the priming system Carefully dismantle the priming system clean it up or replace the components if necessary The engine runs fine but the pump output is low The restricti...

Page 22: ...E PUMPS MFG incurs no liability under this warranty or otherwise for equipment which has been abused altered or improperly maintained or for equipment which has been returned for inspection or repair...

Page 23: ...T direct to ensure you have the latest version 13 Contact Us For repair or questions about warranties please contact your local C E T fire pumps dealer E mail service fire pump com Tel 1 450 568 2719...

Reviews: