C650 & C650R User 

Manual Page 10 

 

2.2

 

PRESENTATION  
2.2.1

 

C650 Tower Model: 

 

UPS Module 

Front view 

1.

 

ventilation area 

2.

 

LCD module, including 
2(1) button 
2(2) LCD screen 
2(3) LED indicator 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Tower UPS 

 

 

 

 

Tower UPS 

6-10kVA C model   

 

 

 

6-10kVA B model 

 

 

 

 

 

 

 

 

 

for UPS connect with user’s own EBM 

see in chapter 3.4.3 

Battery cable (20 batt.)  

for UPS connect with user’s own EBM 

Rail kit 

Rail kit for R model in Rack installing 

See in chapter 3.3.2 

Gland kit 

Gland kit for R model 

For R UPS/MBP model 

Gland kit for Tower model 

For Tower UPS model 

Summary of Contents for C650

Page 1: ...TALLATION AND USER GUIDE THE C650 SERIES An uninterruptible power supply UPS incorporating online double conversion technology which eliminates all mains power disturbances and IOT software www certaups com For assistance please contact your local CertaUPS partner ...

Page 2: ...del 15 3 4 Power cables connection 18 3 4 1 Input Output wiring specifications 18 3 4 2 Wiring for AC Cable AC source to UPS 18 3 4 3 Wiring with external battery module C650 C650R EBM DC source to UPS 19 3 4 4 Wiring with RT MBP MBP source to R T UPS only 20 4 PARALLEL SYSTEM INSTALLATION AND OPERATION OPTIONAL 21 4 1 WIRING FOR AC CABLE 21 4 2 WIRING FOR PARALLEL SIGNAL CABLE 22 4 3 PARALLEL SYS...

Page 3: ...onal 29 6 6 SOFTWARE 30 6 6 1 Winpower 30 6 6 2 WinPower View APP 31 7 UPS MAINTENANCE 32 UPS CARE 32 7 1 TRANSPORTING THE UPS 32 7 2 STORING THE UPS 32 7 3 BATTERY REPLACEMENT 33 7 4 REPLACING THE EBM 33 7 5 RECYCLING A UPS 34 8 TROUBLESHOOTING 35 8 1 ALARMS FAULTS 35 8 2 SILENCING THE ALARM 37 9 TECHNICAL DATA 37 9 1 BLOCK DIAGRAM 37 9 2 UPS SPECIFICATION 37 ...

Page 4: ...the system It should be opened exclusively by qualified service personnel The system must be properly grounded The battery supplied with the system contains small amounts of toxic materials To avoid accidents the directives listed below must be observed Servicing of batteries should be performed by personnel knowledgeable about batteries and the required precautions When replacing batteries replac...

Page 5: ...tem l Never block the ventilation grates of the system l Never expose the system to direct sunlight or source of heat l If the system must be stored before installation storage must be in a dry place l The admissible storage temperature range is 25 C to 55 C without battery 15 C to 40 C with battery l TN S IT TN C TT of the electrical supply system may be connected by UPS l This UPS may be provide...

Page 6: ... IoT Ethernet default and Wireless optional Dot matrix LCD supports multi language ECO Mode Start able without battery 1 2 Environmental Protection Products are developed according to an eco design approach Substances This product does not contain CFCs HCFCs or Asbestos Packing To improve waste treatment and facilitate recycling separate the various packing components The cardboard we use comprise...

Page 7: ...BM 124 RACK MODEL PRODUCT NET WEIGHTS kg UNIT SIZE WxDxH mm C650R 060 C 13 6 438x540x88 2U C650R 100 C 15 5 C650R 060 B 13 3 C650R 100 B 15 2 EBM 240 9AH 60 5 438x559x129 3U EBM 240 7AH 56 1 Optional modules and accessories If you wish to order other types of function modular or accessories please contact distributors partners Type Description Remark R MBP R 6K 10K MBP For RT 1 1 model only Intell...

Page 8: ...reen 2 3 LED indicator Tower UPS Tower UPS 6 10kVA C model 6 10kVA B model for UPS connect with user s own EBM see in chapter 3 4 3 Battery cable 20 batt for UPS connect with user s own EBM Rail kit Rail kit for R model in Rack installing See in chapter 3 3 2 Gland kit Gland kit for R model For R UPS MBP model Gland kit for Tower model For Tower UPS model ...

Page 9: ...nput switch 11 External battery port 12 Maintenance bypass switch optional default is yes EBM EXTERNAL BATTERY MODULE FRONT VIEW 1 Ventilation area 1 EBM port 1 2 EBM label 2 EBM port 2 i 3 Fuse board cover ii replace EBM fuse iii 4 EBM detection Box iv RJ45 port 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 C...

Page 10: ...5 for IoT function 4 USB 5 Wireless HDMI For IoT function 6 RPO DRY in out 7 PARALLEL SLOT 8 RJ45 for EBM detect RT MBP detect 9 AC Input Output port Terminal Block 10 Breaker of input only for 1 1 model optional default is no 11 External battery port EBM EXTERNAL BATTERY MODULE Front view 1 EBM label area 2 EBM label Rearview 1 Fuse board cover replace EBM fuse 2 EBM port 1 3 EBM port 2 4 EBM det...

Page 11: ...INSPECTING Unpacking the unit in a low temperature environment may cause condensation to occur in and on the cabinet Do not install the unit until the inside and outside of the unit are absolutely dry hazard of electric shock If any equipment has been damaged during shipment keep the shipping cartons and packing materials for the carrier or place of purchase and file a claim for shipping damage If...

Page 12: ...gulations concerning waste 3 2 CHECKING THE ACCESSORY KIT Verify that the following additional items are included with the unit Tower model Tower Rack C650 060 B C650 100 B C650 100 C C650 100 C EBM C650R 060 C C650R 100 C C650R 060 C C650R 100 C EBM Battery cable O O EBM detection cable USB cable RS232 cable O O O O Parallel cable O O O O Tower foot O Quick start EBM User manual UPS Extension pla...

Page 13: ...BM installation steps are the same as UPS as above It is recommended to place EBM modular to UPS s left side 3 3 2 Rack model Rack models support 2 installation modes Rack installation and Tower installation 1 To keep good ventilation please keep a free space of at least 500mm at least at the front rear panels of modules 2 Do not carry by the front or rear panel of the module during installation R...

Page 14: ... Manual Page 16 Fasten the rail kit to the cabinet with 8pcs M5 screws washers as below 2 Install Rack ear to the unit by the M4 screws flat head 3 Slide the unit into rail kit and ensure rack mounting screw is tight ...

Page 15: ...o tower orientation 2 Set up the Tower foot then place the unit into Tower foot EBM model 1 Set up the Extension plate as below and install it to Tower foot from UPS 2 Place the UPS EBM into Tower foot individually Place the EBM module to UPS s right side and align with the front panel ...

Page 16: ...l wiring regulations regarding back feed protection requirements Recommended cable minimum cross sectional Model C650 060 C C650 100 C Protective earthing conductor 10mm2 10mm2 Input L N cable 6mm2 10mm2 Output L N cable 6mm2 10mm2 Battery cable 6mm2 10mm2 The length of the output cable is recommended not to exceed 10 meters otherwise it may cause radio interference If the length of the output cab...

Page 17: ... 1 Make sure the UPS is completely off before connecting or disconnecting the EBM 2 Before connecting the EBM make sure that the EBM specification is compatible with the UPS configuration 3 Do not reverse the polarity of the external battery Connect with the configured EBM Connect EBM to UPS with Battery cable and EBM detection cable TOWER EBM Note 1 Extended runtime with up to 6 Extended Battery ...

Page 18: ...le is needed for installation it must follow cable specification and the maximum length of battery cable 10 meters for application 2 If a length of battery cable over 10 meters is required please contact distributors agents for details 3 4 4 Wiring with Rackmounted bypass Rackmount bypass is an optional extra to implement the maintenance bypass switching function to ensure that the output of the s...

Page 19: ... to 3 UPS systems can be connected in parallel to configure a sharing and redundant output power In parallel the mechanical installation for each module is the same as the single system For more details please refer to Chapter 3 3 Parallel system AC cable diagram 4 1 WIRING FOR AC CABLE Tower model parallel system Rack model parallel system ...

Page 20: ...Press the button continuously on one UPS of the system then the system will start to turn on and enter line mode 3 Regulate the output voltage of each UPS separately and check if the output voltage difference is less than 0 5V among the parallel system If the difference is more than 0 5V the UPS need to be calibrated 4 If the output voltage difference is less than 0 5V press button continuously on...

Page 21: ...uble shooting for more information THE BUTTONS The button Function Illustration Power on Press the Button for 100ms 1s will power on the UPS in standby Turn on When the Unity is powered on press the button for 3s can turn on the UPS Turn off Press the button 4s can turn off the UPS Scroll up Press to scroll up the menu option Scroll down Press to scroll down the menu option Enter menu Select Confi...

Page 22: ...econds Battery mode A utility failure has occurred and the UPS is powering the equipment with battery Prepare your equipment for shutdown 1 beep every 1 seconds Battery mode with battery low This warning is approximate and the actual time to shutdown may vary significantly High Efficiency mode When the mains are lost or abnormal the UPS will transfer to Line mode or Battery mode and the load is su...

Page 23: ... stored Measurements Load W VA A P Input L1 Output V Hz Input L2 Input L3 V Hz if they exist Battery min V EBM DC Bus V Temperature Control Load segment Load segments enable or disable Start battery test Single mode Single battery test parallel mode Starts a manual battery test in stand alone mode Or starts a single battery test in parallel mode Parallel UPS battery test parallel mode Starts a man...

Page 24: ...Enabled Enabled Enabled Site wiring fault Enabled Disabled Disabled Overload pre alarm 50 105 105 External battery Auto detection Manual EBM 0 6 Manual Ah 0 300Ah Auto detection 0 EBM 0 Ah Charger current 1 4A for 6 10k 2 12A for 6 10KS 1 4A for 6K 2A for 10K 4A for 6 10KS Dry in signal Disabled Remote on Remote off Forced bypass Disabled Dry out signal Load powered On bat Low bat Bat open Bypass ...

Page 25: ... UPS WITH UTILITY 5 6 STARTING THE UPS ON BATTERY Before using this feature the UPS must have been powered by utility power with output enabled at least once Battery start can be disabled See the Cold start setting in start restart 5 7 UPS SHUTDOWN ...

Page 26: ...mmediately and continues to alarm RPO Comments Connector type 1 3mm Maximum wires External breaker specification 60 V DC 30 V AC 20 mA max Reset 1 Check the RPO connector status 2 Clear fault state through LCD Dry In Dry in function can be configured see Settings Dry in Dry in Comments Connector type 1 3mm Maximum wires External breaker specification 60 V DC 30 V AC 20 mA max Dry Out Dry out is th...

Page 27: ... an account log in follow the instructions of the app 5 Tap on the upper right corner scan the SN barcode on the UPS label to add a device For more detailed information and Q A about the IoT and APP please refer to the HELP menu in the app Wireless network connection The wireless module is optional please contact your local distributor for details 6 4 Modbus TCP Built in Ethernet port offers Modbu...

Page 28: ...or analysis Multi language support English Italian Turkish Spanish French Portuguese Polish Thai Germanic Russian and Japanese Requires a GSM modem not supplied WinPower installation STEP ONE Go to http www ups software download com content ups download software download html download winpower STEP TWO Choose the operating system you need and follow the instruction described on the website to down...

Page 29: ...6 2 CertaUPS APP WinPower View is a mobile app that allows you to centralise monitored UPS by connecting them to the cloud Please download it from the Google Play Store or Apple APP store Please refer to chapter 6 3 for IoT connection ...

Page 30: ...from mains power Place the UPS on a flat stable surface with the front of the cabinet facing you Remove the UPS front cover Disconnect the internal battery connectors Replace the UPS front cover To avoid damage and to prevent DOA s always use a reputable courier for all equipment transportation 7 2 STORING THE UPS Where UPS equipment is stored for a long period the batteries must be recharged ever...

Page 31: ...e following precautions Remove watches rings or other metal objects Use tools with insulated handles Do not lay tools or metal parts on top of batteries Wear rubber gloves and boots 7 4 REPLACING THE EBM For the C650 tower module Turn the MBS to bypass and switch off the input and then replace the EBM s For the C650R rotation module If a PDU is connected to the UPS turn the MBS to bypass and switc...

Page 32: ...disposal of batteries is required Refer to your regulations for disposal requirements DO NOT open or modify the battery or batteries Released electrolyte is toxic and harmful to the skin and eyes DO NOT discard the UPS or the UPS batteries in the general waste This product contains sealed lead acid batteries and must be disposed of responsibly For more information contact your local recycling cent...

Page 33: ...inking Some alarms may be announced by a beep every 1 second Example Battery low Faults are announced by a continuous beep and red LED recorded into the Event log Example Out Short circuit To check the Event log By pressing on the menu of Event log Scroll through the listed events or faults The following table describes typical conditions 8 1 ALARMS FAULTS TO REGISTER A FAULT PLEASE VISIT CERTAUPS...

Page 34: ... backup time Protect load equipment in time FAULT Problem Displayed Possible cause Remedy Inverter overload Overload Check the loads and remove some noncritical loads Check if some loads are failed Bypass overload Overload Check the loads and remove some noncritical loads Check if some loads are failed Out short circuit abnormally low impedance placed on its output and considers it a short circuit...

Page 35: ...ion to resolve the condition If an alarm status changes the alarm will need to be silenced again 9 TECHNICAL DATA 9 1 BLOCK DIAGRAM 9 2 UPS SPECIFICATION Tower UPS Model C650 060 B C650 060 C C650 100 B C650 100 C Capacity 6kVA 6kW 10kVA 10kW INPUT Input Voltage Range 110VAC 276VAC Rated Voltage 220 230 240VAC Frequency 50Hz 60Hz Frequency Range 45Hz 55Hz 50Hz system 54Hz 66Hz 60Hz system load 60 ...

Page 36: ...A 2A 4A Charging range 1 4A 2 12A 1 4A 2 12A OTHER MODE CVCF Yes deterating to 60 load HMI Display Dot matrix LCD optional segment LCD Language Multi language USB USB 2 0 with HID power device RS232 Yes DB9 Dry in out 1 programmable dry in 1 programmable dry out RPO Yes Intelligent Slot Yes Network Card Optional C NMC Modbus Card Optional C Modbus Dry Contactor Card Optional C Relay Wireless Modul...

Page 37: ...VAC 276VAC Rated Voltage 220 230 240VAC Frequency 50Hz 60Hz Frequency Range 45Hz 55Hz 50Hz system 54Hz 66Hz 60Hz system load 60 Power Factor 1 Rated current 35A 45A 54A 63A OUTPUT Voltage Regulation AC Mode 220 230 240V AC Rated Frequency 50 Hz 60 Hz AC Outlets Terminal Block Maximum Power Factor 1 Voltage accuracy 1 Transfer Time Line Battery 0ms Transfer Time INV Bypass 0ms Wave form Pure sine w...

Page 38: ...ptional C WIFI IOT Ethernet Port RJ45 Monitoring Software Winpower CertaUPS Monitor App PHYSICAL Dimension WxDxH mm 438 x 540 x 88 2U Net weight Kg 14 14 16 16 IP Protection Level IP20 ENVIRONMENT Operating Temperature 0 40 C derating 50 above 40 C excluding batteries Relative Humidity 0 95 non condensing Operating Altitude 0 3000m the load derating 1 every up 100m 1000 3000m Storage temperature w...

Page 39: ...0R User Manual Page 41 A FULL GLOSSARY OF TERMS CAN BE FOUND AT WWW CERTAUPS COM SUPPORT UPS GLOSSARY FOR FURTHER INFORMATION OR ASSISTANCE PLEASE CONTACT YOUR CertaUPS REPRESENTATIVE OR VISIT WWW CERTAUPS COM ...