CERONIX LCD MONITOR SPECIFICATION AND SERVICE MANUAL
76
33. 24V 2
-
LAMP INVERTER
CERONIX PART NUMBER CPM2236A
INPUT: 24VDC, .45A
OUTPUT: CCFL LAMP CURRENT RANGE 3.5
-
8.0mA @ 50kHz
CN1 DC SUPPLY AND CONTROL
PIN
FUNCTION
1
+24VDC
2
+24VDC
3
GROUND
4
GROUND
5
BRIGHT ADJUST
6
GROUND
7
ON/OFF CONTROL
CN2, CN3 CCFL LAMP CONNECTION
PIN
FUNCTION
1
CCFL HIGH VOLTAGE
2
CCFL RETURN