Metrologic MS1690 2D Scanner 
Installation Guide 

 
 
 
 

 

 
 

Revision 1.0 

 

Summary of Contents for Metrologic MS1690 2D

Page 1: ...Metrologic MS1690 2D Scanner Installation Guide Revision 1 0...

Page 2: ...lease The latest version of this document can be found in the following places Internally for Cerner associates in the Cerner Knowledge Repository KR using the search function with the keywords Metrol...

Page 3: ...Contents 3 Overview 4 LED and Beep Meanings 5 USB Scanner Setup 6 PS 2 Keyboard Wedge Scanner Setup 7 RS 232 Serial Scanner Setup 8 Symbology Selection 10 Setting up the Scanner for Cerner Millennium...

Page 4: ...ee the above two circles In this example the model number is MS1690 47 Note Each scanner model is specifically designed for a particular interface Do not mix scanners and interfaces This documentation...

Page 5: ...Beep When the scanner successfully reads a bar code it will beep once and the White LED will turn on indicating data is being transmitted If the host is not ready to accept the information the scanner...

Page 6: ...f the scanner and to an unused USB port on the PC Wait for the 3 beeps indicating that the scanner is ready 2 The scanner should be pre configured for use with a USB interface You should not have to s...

Page 7: ...terface cable to the scanner and connect the male PS 2 connector to the keyboard port on the PC or thin client 5 Plug the keyboard into the female PS 2 cable on the interface cable PS 2 Cable Connecti...

Page 8: ...rds Keyport Internally for Cerner associates on My Cerner using the search function with the keywords Keyport Externally for clients and Cerner associates on www cerner com under the Support tab Mille...

Page 9: ...are are set properly 9600 Baud Even Parity 7 Data Bits 1 Stop Bit 7 Scan the following bar codes 9 9 9 9 9 8 Factory Defaults 9 9 9 9 9 9 Enter Exit Config Mode 3 1 6 0 2 5 Even Parity 4 1 5 8 5 0 960...

Page 10: ...0 4 1 4 Enable RSS Limited 1 1 4 9 1 4 No RSS Limited App 1 1 4 9 1 5 No RSS Limited Sym 1 0 0 2 1 7 Enable Code 39 Full 1 0 0 1 1 0 Enable Standard 2 of 10 Metrologic MS1690 Focus Installation Guide...

Page 11: ...lease proceed to the section titled Set Postamble for Cerner Classic Cerner Millennium Applications Metrologic MS1690 Focus Installation Guide 11 Cerner Confidential and Proprietary All rights reserve...

Page 12: ...fix Setting up the Scanner for Cerner Classic Applications Note If you are not running Cerner Classic applications skip this section Scan the following barcodes to set up the scanners suffix to a Carr...

Page 13: ...the bar code until either it succeeds or the bar code is removed from the scanner s field of view When scanner successfully reads the bar code it will beep once the white LED will flash and the decode...

Page 14: ...7 15370 0 0 0 15370 0 0 0 15370 0 0 0 15370 0 0 0 15370 Note The last block of numbers is the firmware revision level In this case it would be 15370 Scan the following barcode to turn off Scan Count 1...

Page 15: ...y All rights reserved This document contains confidential information which may not be reproduced or transmitted without the express written consent of Cerner Corporation A B C 1 2 3 Code 39 Normal A...

Page 16: ...a lot of information in a small space Data Matrix This is a sample of the 2D Data Matrix symbology This symbology can store a lot of information in a small space 16 DS3408 Installation Guide PCs and T...

Page 17: ...s 17 Cerner Confidential and Proprietary All rights reserved This document contains confidential information which may not be reproduced or transmitted without the express written consent of Cerner Co...