FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 311 of 597
Parameter
Definition
Additional Text
Additional text that has been added to the system-defined description of the alarm by
users. You can edit the text in the Alarm Configuration
–
Edit page. See Editing an
Service Affecting
Indicates whether the alarm is considered by the system to be service-affecting (on)
or not (off).
11.3.2
Viewing the Probable Cause and Corrective Actions for an Alarm
Type
Most alarm types include a system-defined probable cause and suggested
corrective actions. To view an alarm type's probable cause and corrective
actions, click + on the left side of the alarm type's row in the Alarm
Configuration page. The Probable Cause and Corrective Actions appear
underneath the alarm type's row, as shown below. If there is no +, that means
no Probable Cause and Corrective Actions are defined for the alarm type.
Figure 238: Alarm Configuration Page
– Expanded
11.3.3
Editing an Alarm Type
To change the severity of an alarm type and add additional text to the alarm
type's description:
1 Select the alarm type in the Alarm Configuration page (Figure 237).
2 Click Edit. The Alarm Configuration - Edit page opens.
Figure 239: Alarm Configuration - Edit Page