2 Click Add. The Policer Profile - Add page opens.
Figure 151: Policer Profile - Add Page
3 Configure the profile’s parameters. See Table 45 for a description of the
policer profile parameters.
4 Click Apply, then Close.
Table 45: Policer Profile Parameters
Parameter
Definition
Profile ID
A unique ID for the policer profile. You can choose any unused value from 1 to 250.
Once you have added the profile, you cannot change the Profile ID.
Description
A description of the policer profile.
Policer type
Read-only. The type of policer. Always set to MEF-TRTCM.
CIR
Enter the Committed Information Rate (CIR) for the policer, in bits per second. Permitted
values are 0, or 64,000 through 1,000,000,000 bps. If the value is 0, all incoming CIR
traffic is dropped.
CBS
Enter the Committed Burst Rate (CBR) for the policer, in Kbytes. Permitted values are 2
through 128 Kbytes.
EIR
Enter the Excess Information Rate (EIR) for the policer, in bits per second. Permitted
values are 0, or 64,000 through 1,000,000,000 bps. If the value is 0, all incoming EIR
traffic is dropped.
EBS
Enter the Excess Burst Rate (EBR) for the policer, in Kbytes. Permitted values are 2
through 128 Kbytes.