FibeAir IP-20C/S/E
User Guide
Ceragon Proprietary and Confidential
Page 146 of 597
3 In the Thresholds table, select the radio for which you want to configure
thresholds.
4 Click Edit. The Radio Thresholds – Edit page opens.
Figure 102: Radio Thresholds
– Edit Page
5 Configure the thresholds, as described in Table 25.
6 Click Apply, then Close.
Table 25: PM and BER Thresholds
Parameter
Definition
Radio Location
Identifies the carrier (Slot 2, port 1 or Slot 2, port 2).
Note: Only relevant for IP-20C units.
RX Level Threshold 1 (dBm)
Specify the threshold for counting exceeded seconds if the RSL is below
this level.
RX Level Threshold 2 (dBm)
Specify a second threshold for counting exceeded seconds if the RSL is
below this level.
TX Level Threshold (dBm)
Specify the threshold for counting exceeded seconds if the TSL is below
this level.
MSE PM Threshold (dB)
Specify the modem MSE (Mean Square Error) threshold for calculating
MSE Exceed Threshold seconds.
XPI PM Threshold (dB)
Specify the modem XPI threshold for calculating XPI Exceed Threshold
seconds.
Excessive BER Threshold
Select the level above which an excessive BER alarm is issued for errors
detected over the radio link.
Signal Degrade BER Threshold
Select the level above which a Signal Degrade alarm is issued for errors
detected over the radio link.