3 Partially attach the OCU-radio unit to the Branching Pole Profile with the two
M8-30 screws included in the OCU kit, along with the remaining helical and
flat washers, as shown in
It is very important that at this point in the
procedure, you do not fully tighten the screws. The screws should only be fully
tightened after all the U-Bends and (if necessary) Terminations have been
attached!
2
8
5
3
1
Figure 46: Securing the OCU-Radio Unit to the Branching Pole Profile
Waveguide Assemblies
At this point in the installation, you must install all required waveguide
assemblies, such as U-Bends, Flexible Waveguides, and Terminations. For
instructions, refer to the specific type of configuration you are installing in
Section 7.2,
Channel Filter-Based Branching
Tightening the M8-30 Screws
When you have finished installing all waveguides, and all of the radio ports have
been covered, you must fully tighten the two M8-30 screws that attach the OCU-
radio unit to the Branching Pole Profile as shown above in