User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 548 of 825
Ceragon Proprietary and Confidential
Table 119: RSL and TSL PMs (CLI)
Parameter
Description
Interval
The number of the interval: 1-30 for daily PM
reports, and 1-96 for 15 minute PM reports.
Integrity
Indicates whether the values received at the time
and date of the measured interval are reliable.
"1" in the column indicates that the values are
not reliable due to a possible power surge or
power failure that occurred at that time.
Min RSL (dBm)
The minimum RSL (Received Signal Level) that
was measured during the interval.
Max RSL (dBm)
The maximum RSL (Received Signal Level) that
was measured during the interval.
Min TSL (dBm)
The minimum TSL (Transmit Signal Level) that
was measured during the interval.
Max TSL (dBm)
The maximum TSL (Transmit Signal Level) that
was measured during the interval.
TSL exceed threshold seconds
The number of seconds the measured TSL
exceeded the threshold during the interval. See
Configuring TSL Thresholds (CLI)
RSL exceed threshold1 seconds
The number of seconds the measured RSL
exceeded RSL threshold 1 during the interval. See
Configuring RSL Thresholds (CLI)
RSL exceed threshold2 seconds
The number of seconds the measured RSL
exceeded RSL threshold 2 during the interval. See
Configuring RSL Thresholds (CLI)
16.6.7
Configuring the Signal Level Threshold (CLI)
To set the BER (Bit Error Rate) level above which a Signal Degrade alarm is issued
for errors detected over the radio link, enter the following command in radio
view:
radio [x/x]>modem signal-degrade set threshold 1e-7
To display the Signal Degrade BER threshold, enter the following command in
radio view:
radio [x/x]>modem signal-degrade show threshold