2 Click
Edit
. The Voltage Alarm Configuration
–
Edit page opens.
Figure 332: Voltage Alarm Configuration
–
Edit Page
3 Select the thresholds you want in the
Undervoltage clear threshold (V)
,
Undervoltage raise threshold (V)
,
Overvoltage clear threshold (V)
, and
Overvoltage raise threshold (V)
fields. The configurable values for these
thresholds are 0-100V.
4 Click
Apply
.
In addition to adding the ability to configure these alarm thresholds, CeraOS 10.5
adds PMs that indicate, per 15-minute and 24-hour periods:
•
The number of seconds the unit was in an undervoltage state during the
measured period.
•
The number of seconds the unit was in an overvoltage state during the
measured period.
•
The lowest voltage during the measured period.
•
The highest voltage during the measured period.
These PMs are displayed via CLI. For instructions, see