Cables 

Part Number 

Marketing Model 

Marketing Description 

WA-0242-1 

X-WSC-E1/T1 

E1/T1 WSC x-ed cable 

WA-0246 IDU-EXT-ALARMS-CBL-2.5m 

IDU External Alarms open cable 2.5m 

WA-0259 CBL-16E1-CB-120-75 

16E1 

cable MDR/2xDB44 5m to CB-120-75 

WA-0275 

IDU-UC-CBL-2m 

User channel cable 2m D-type 9 pin male 

WA-0276-0 

IP10-CBL-16IO-PROT-0.6m 

IP-10 16 I/O port protection cable straight 0.6m 

WA-0277-0 

IP10-CBL-16IO-5M 

IP-10 16 I/O port cable open 5M 

WA-0278-0 

IP-10-CBL-16IO-10M 

IP-10 16 I/O port cable open 10M 

WA-0284-0 IP10-CBL-16IO-XED-0.6m 

IP-10 16 I/O port crossed cable 0.6m 

WA-0309-0 

IP-10-CBL-16IO-25M 

IP-10 16 I/O port cable open 25M 

Panels 

Part Number 

Marketing Model 

Marketing Description 

EN-0254-0 IP10-ETH-16E1-PROT-PANEL  IP-10 Eth + 16E1 protection panel 

EN-0256-0 IP10-ETH-16T1-PROT-PANEL  IP-10 Eth + 16T1 protection panel 

EN-0258-0 IP10-16E1-PROT-PANEL 

IP-10 16E1 protection panel 

EN-0259-0 IP10-16T1-PROT-PANEL 

IP-10 16T1 protection panel 

EN-0262-0 IP10-ETH-PROT-PANEL 

IP-10 Eth only protection panel 

Summary of Contents for FibeAir IP-10

Page 1: ...FibeAir IP 10 IDU Installation Guide Part ID BM 0137 0 Doc ID DOC 00018767 Rev a 03 September 2008...

Page 2: ...able for errors contained herein or for incidental or consequential damage in connection with the furnishing performance or use of this document or equipment supplied with it Information to User Any c...

Page 3: ...t at the Site 1 2 Installation Requirements 1 2 FibeAir IP 10 Description 1 4 Installing the IDU in a Rack 1 5 Grounding the IDU 1 7 Connecting the IDU 1 9 Configuring the IDU 1 10 Appendix A Line Int...

Page 4: ...ye hazard CLASS 1 LASER PRODUCT Complies with IEC 60 825 1 1993 A1 1997 A2 2001 and EN 60825 1 1994 A1 1996 A2 2001 General Equipment Precautions Use of controls adjustments or performing procedures o...

Page 5: ...ore touching components inside the device all electrostatic must be discharged from both personnel and tools RoHS Compliance Declaration Electronic Information Products Declaration of Hazardous Toxic...

Page 6: ...e aux normes CEI 60 825 1 1993 A1 1997 A2 2001 et EN 60825 1 1994 A1 1996 A2 2001 Pr cautions g n rales relatives l quipement L utilisation de commandes ou de r glages ou l ex cution de proc dures aut...

Page 7: ...r die Augen LASERPRODUKT DER KLASSE 1 Entspricht den Normen IEC 60 825 1 1993 A1 1997 A2 2001 sowie EN 60825 1 1994 A1 1996 A2 2001 Allgemeine Vorsichtsma nahmen f r die Anlage Wenn andere Steuerelem...

Page 8: ...nclude trees new buildings window cleaners on the roof snow that may accumulate in front of the antenna etc The site should be accessible to certified personnel only Note about Antenna Location As wit...

Page 9: ...or missing parts If any part is damaged or missing contact your local distributor Installation Requirements Required Tools The following tools are required to install the IDU Philips screwdriver for...

Page 10: ...circuit overcurrent protective device rated 15 A must be incorporated in the building wiring CAUTION This equipment is designed to permit connection between the earthed conductor of the DC supply circ...

Page 11: ...ative2 capability for optimal traffic delivery and modular architecture for all sites Tail Chain Agg3 Agg2 this state of the art radio platform offers the best approach to IP migration for advanced ne...

Page 12: ...o interfaces that connect to the OSP or its wiring These interfaces are designed for use as intra building interfaces only and require isolation from the exposed OSP cabling The addition of Primary Pr...

Page 13: ...FibeAir IP 10 IDU Installation Guide 1 6 IDU Dimensions The following illustration shows the dimensions in millimeters of the FibeAir IP 10 IDU...

Page 14: ...ion in a Common Bonding Network CBN Only copper wire should be used The wire must be at least 6 AWG Connector and connection surfaces must be plated Bare conductors must be be coated with antioxidant...

Page 15: ...ply Notes When selecting a power source the following must be considered DC power can be from 40 5 VDC to 72 VDC Recommended Availability of a UPS Uninterrupted Power Source battery backup and emergen...

Page 16: ...ibed in Appendix C Protection Information Interface Descriptions The following photo shows the different IDU ports and their functions IDU Front Panel The IDU front panel includes the following auxili...

Page 17: ...connectors Important Make sure that the inner pin of the connector does not exceed the edge of the connector The cable should have a maximum attenuation of 30 dB at 350 MHz Configuring the IDU After t...

Page 18: ...s are sent to FibeAir Main Channel Interfaces Main channel interfaces include the following Gigabit Ethernet Optical 1000Base SX Multi Mode Wavelength 850 nm Receptacle MSA compliant SFP Small Form Fa...

Page 19: ...orts 16 per unit optional Timing mode Retimed Framing Unframed full transparency Coding E1 HDB3 T1 AMI B8ZS Range 5 m Line Impedance 120 100 balanced Optional module for 75 unbalanced Compatible Stand...

Page 20: ...e Out of Band Management Connector Shielded RJ 45 Used with UTP Cat 5 Protocols supported Ethernet 10 100BaseT half or full duplex Timing mode Retimed Range 100 m Impedance 100 Order Wire Channel Inte...

Page 21: ...uide A 4 User Channel Interface The user channel is a CVSD audio channel that delivers 64 Kbps via an RJ 45 connector The interface can be used for one of the following Asynchronous RS 232 Asynchronou...

Page 22: ...This appendix provides pin outs for FibeAir IDU connectors including the following y External Alarms Connector y Protection Wayside Management Connector y Power Connector y 16 x E1 T1 Connector y Ethe...

Page 23: ...3 4 EXT_IN2 Input External input alarm 2 5 EXT_IN1 Input External input alarm 1 6 GND GND GND 7 RELAY_1_N O Output Relay 1 normally open pin 8 RELAY_1_C Output Relay 1 common pin 9 RELAY_1_NC Output...

Page 24: ...T TIP1 35 OUT RING1 Ch1 Tx TWISTED PAIR 2 OUT TIP2 36 OUT RING2 Ch2 Tx TWISTED PAIR 3 OUT TIP3 37 OUT RING3 Ch3 Tx TWISTED PAIR 4 OUT TIP4 38 OUT RING4 Ch4 Tx TWISTED PAIR 5 OUT TIP5 39 OUT RING5 Ch5...

Page 25: ...x TWISTED PAIR 21 IN TIP3 55 IN RING3 Ch3 Rx TWISTED PAIR 22 IN TIP4 56 IN RING4 Ch4 Rx TWISTED PAIR 23 IN TIP5 57 IN RING5 Ch5 Rx TWISTED PAIR 24 IN TIP6 58 IN RING6 Ch6 Rx TWISTED PAIR 25 IN TIP7 59...

Page 26: ...6 68 IN RING16 Ch16 Rx TWISTED PAIR 17 SHELL SHIELD 18 SHELL SHIELD 51 SHELL SHIELD 52 SHELL SHIELD Ethernet 10 100 1000 Connector Pin Out The Ethernet 10 100 1000 connector is an RJ 45 8 pin female t...

Page 27: ...air Out Tx 3 6 Twisted Pair In Rx 4 5 Not Connected 7 8 Not Connected User Channel Connector Pin Out The user channel connector is an RJ 45 connector Pin Asynchronous RS 232 Asynchronous V11 I O 1 NC...

Page 28: ...protection equipment Protection Patch Panel In IP 10 protection configurations a protection patch panel is used to connect the units and provide protection switching As shown in the illustration abov...

Page 29: ...T1 MDR Connector WA 0277 0 5 meters WA 0278 0 10 meters WA 0309 0 25 meters Optical splitter used for GbE 1 1 systems see the following section AO 0038 0 AO 0039 0 AO 0059 0 AO 0060 0 User Optical Gb...

Page 30: ...DU Installation Guide C 3 GbE Optical Splitter The following illustration shows the rear side of the IP 10 protection panel with the optical splitter The optical splitter is an LC LC female adapter Op...

Page 31: ...port protection cable straight 0 6m WA 0277 0 IP10 CBL 16IO 5M IP 10 16 I O port cable open 5M WA 0278 0 IP 10 CBL 16IO 10M IP 10 16 I O port cable open 10M WA 0284 0 IP10 CBL 16IO XED 0 6m IP 10 16...

Page 32: ...scription AO 0033 0 OP SM CBL LC SC DPLX 15M Duplex Optical Cable LC SC SM 15M Pairs of Fiber Patchcord Single mode LC SC Length 15M Duplex PVC 2mm cable with LC connector type on one end and SC conne...

Page 33: ...COLOR 3M 2MM O D AO 0067 0 OP MM CBL LC LC DPLX 6M Duplex Optical Cable LC LC MM 6M DUPLEX FIBER OPTIC MM PATCH CORD WITH LC UPC LC UPC Tx TO Tx 62 5 125 ORANGE COLOR 6M 2MM O D AO 0071 0 OP SM CBL L...