6.  Care & Maintenance

6.1  Maintenance Inspection

• Examine the external condition of the battery. The top of battery and terminal connections should be 

clean, dry, and free of corrosion.

• Check battery cables and connections are firmly secure.
• Check the battery state of charge (SOC) regularly. When not in use the Century Lithium Pro battery will 

partially self-discharge. 

• Depending on the charging profile used, overtime the series and parallel configured batteries may not 

be equally charged. To fully balance batteries in either of these configurations, maintenance charge each 
battery individually at periodic intervals.

6.2 Cleaning

• Before cleaning, disconnect the battery from the charging source and the load.
• The surface of LFP battery can be cleaned with a soft, dry cloth made of non-electroconductive material.
• Keep the area around batteries clean, dry, and away from any flammable materials.

7. Storage 

• Disconnect the battery from all electrical loads and from the charger to eliminate potential parasitic loads 

that may discharge the battery.

• Cover the LFP battery terminals with suitable non-electroconductive material (e.g. insulating tape or 

plastic caps).

• Observe the minimum and maximum storage temperatures.
• Store in a cool, dry place. There is no specific ventilation requirements for Century Lithium Pro batteries, 

however sufficient airflow should be ensured to prevent excessive heat build-up.

• Keep area free from flammable materials. 
• Keep out of reach of children and animals.
• Do not store in direct sunlight.
• The battery should be stored at a state of charge of between 40% ~60% of its nominal capacity.  

Storing a deep discharged battery can result in permanent damage and reduced run time. 

• Allowing the battery to self-discharge to a severely low state of charge may result in the battery not 

being able to be recovered.

• Check battery every 4 to 6 months, or more frequently in ambient temperatures exceeding 35°C, to 

determine if charging is required.

ADVANCED LiFePO4 TECHNOLOGY 

LITHIUM 

17

Summary of Contents for C12-100XLi

Page 1: ...1 LITHIUM LITHIUM PRO PRO PRO PRO PRO PRO PRO PRO PRO PRO PRO PRO PRO PRO USER MANUAL...

Page 2: ...ntact Century Yuasa Batteries AU 1300 361 161 or NZ 0800 93 93 93 Disclaimer All rights reserved Information contained in this user manual is subject to change without notice or obligation Any informa...

Page 3: ...ating Use 8 4 1 Operating conditions 8 4 2 Bluetooth connection 9 4 3 Charging 14 4 4 Discharging 15 5 Troubleshooting 16 6 Care Maintenance 17 7 Storage 17 8 Transportation 18 9 Disposal Recycling 18...

Page 4: ...ad acid batteries used in RV camper trailer caravan 4WD AUX boot marine and mobility applications This LFP battery should not be used in any applications other than those described in this user manual...

Page 5: ...l of one battery to positive terminal of the next battery Components Construction 1 Handle 2 Positive terminal M8 nut insert 3 Negative terminal M8 nut insert 4 Top cover Flame Retardant ABS PC 5 Posi...

Page 6: ...y before installing Remove charger immediately and contact the dealer if any abnormal smell or noise while on charge or when a discharge is detected Don t s Do not drop impact or puncture the battery...

Page 7: ...which shows the selected cells they are grouped with during the manufacturing process The first number is the batch number and the second number is the sequence within the batch The battery can be con...

Page 8: ...mode Charge activation Connect a charger with 1 2V above the battery voltage Discharge activation Connect a load 5k The following operating ambient temperatures and humidity must be followed Charging...

Page 9: ...tus Battery State of Health Battery Temperature Battery Cycle Battery Alarm Battery Event Information 4 2 1 Installation and Pairing App on iOS or Android Download the App Century Lithium Pro Ensure B...

Page 10: ...series or in parallel each battery can be checked in turn one by one on the same smart device Simply follow the pairing connection process for each individual battery After being connected the battery...

Page 11: ...s standby charge or discharge and battery state of health good or service if below 80 initial capacity b Swiping across from the Basic Info screen will show the Details Info screen This screen shows b...

Page 12: ...500mS or 284 345A for 17mS After 13S up to 3 consecutive times Except at 284A no auto recovery Over Discharge Current 350A for 3S or 560 650A for 8mS After 13S up to 3 consecutive times Except at 560A...

Page 13: ...ontact details App information and user manual can be located in this area and the Sleep mode for the paired battery can also be set d Touching the icon on any of the screen will bring up the Menu scr...

Page 14: ...ready until the cells are balanced After charger has been disconnected allow 30 minutes rest time for the battery cells to balance If charging batteries in series ensure the charging voltage is less t...

Page 15: ...1000W inverter can be connected to avoid damaging the battery including the BMS and the cells Constant current constant voltage charging CCCV is recommended for LFP batteries Refer to diagram below f...

Page 16: ...tooth of the mobile phone does not detect the battery Check the phone s Bluetooth function 6 Battery gets too hot Frequent overload use high current draw Use according to battery specifications Workin...

Page 17: ...loads and from the charger to eliminate potential parasitic loads that may discharge the battery Cover the LFP battery terminals with suitable non electroconductive material e g insulating tape or pl...

Page 18: ...ixed with lead acid and or other battery types at any stage of the recycling process Refer to relevant sections of this manual if any batteries are collected stored and transported for recycling It is...

Page 19: ...CB113 3136 For more information visit centurybatteries com au or call 1300 362 287 centurybatteries co nz or call 0800 93 93 93...

Reviews: