Page 31
Installation and Operation Manual - FW3200
ENGLISH
8.1.4 Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
10" (254 mm)
10" (254 mm)
D
13
½
" (343 mm)
13
½
" (343 mm)
B
23" (584 mm)
23" (584 mm)
E
31 ¾" (806 mm)
31 ¾" (806 mm)
K
48" (1219 mm)
36" (914 mm)
L
70" (1778 mm)
70" (1778 mm)
8.1.5 Mobile Home
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
7
½
" (191 mm)
7
½
" (191 mm)
D
11" (279 mm)
11" (279 mm)
B
24" (610 mm)
24" (610 mm)
E
32 ¾" (832 mm)
32 ¾" (832 mm)
C
12" (305 mm)
12" (305 mm)
F
21 ¾" (552 mm)
21 ¾" (552 mm)
8.1.6 Mobile Home With Heat Shield AC02762
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
3
½
" (89 mm)
3
½
" (89 mm)
D
7" (178 mm)
7" (178 mm)
B
7 ½
" (191 mm)
7 ½
" (191 mm)
E
16 ¼" (413 mm)
16 ¼" (413 mm)
C
5
3/8
" (137 mm)
5
3/8
" (137 mm)
F
15
1/8
" (384 mm)
15
1/8
" (384 mm)
17
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.