Page 8
Installation and Operation Manual - CW2900
ENGLISH
2. General Information
2.1 Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Models
CW2900 (CB00022)
Combustion Technology
Non catalytic
Fuel Type
Dry Cordwood
Recommended heating area (sq. ft.
.
)
1
500 to 2,100 ft
2
(47 to 195 m
2
)
Overall firebox volume
2.4 ft
3
(0.068 m
3
)
EPA loading volume
2.02 ft
3
(0.057 m
3
)
Maximum burn time
1
8 hours
Maximum heat output (dry cordwood)
2
75,000 BTU/h (22.0 kW)
Overall heat output rate (min. to max.)
2 3
14,800 BTU/h to 28,600 BTU/h
(4.34 kW to 8.38 kW)
Average overall efficiency
3
Dry cordwood
69 % (HHV)
4
74 % (LHV)
5
Optimum efficiency
4
77 %
Average particulate emissions rate
5
1.54 g/h (EPA / CSA B415.1-10)
8
Average CO
6
89.4 g/h
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
. Other performances are based on
a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19%
and 25%.
3
As measured per CSA B415.1-10 stack loss method.
4
Optimum overall efficiency at a specific burn rate (LHV).
5
This appliance is officially tested and certified by an independent agency.
6
Carbon monoxide.