Page 31
Installation and Operation Manual - FW2800
ENGLISH
8.1.4 Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
8" (203 mm)
8" (203 mm)
D
11 ½" (292 mm)
11 ½" (292 mm)
B
19" (483 mm)
19" (483 mm)
E
28" (711 mm)
28" (711 mm)
K
48" (1219 mm)
36" (914 mm)
L
78" (1981 mm)
78" (1981 mm)
8.1.5 Mobile Home
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
10" (254 mm)
10" (254 mm)
D
13 ½" (343 mm)
13 ½" (343 mm)
B
20" (508 mm)
20" (508 mm)
E
29" (737 mm)
29" (737 mm)
C
12" (305 mm)
12" (305 mm)
F
20 ¾" (527 mm)
20 ¾" (527 mm)
8.1.6 Mobile Home With Heat Shield AC02762
It is strictly
forbidden
to install a unit with
a single wall pipe
in a
mobile home
.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
6 ½" (165 mm)
6 ½" (165 mm)
B
5" (127 mm)
5" (127 mm)
E
14" (356 mm)
14" (356 mm)
C
3" (76 mm)
3" (76 mm)
F
11 ¾" (298 mm)
11 ¾" (298 mm)
L
84" (2130 mm)
84" (2130 mm)
17
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
Summary of Contents for CB00021
Page 2: ......
Page 6: ...Page 6 Installation and Operation Manual FW2800 ENGLISH CERTIFICATION PLATE ...
Page 48: ...Page 48 Installation and Operation Manual FW2800 ENGLISH Appendix 6 MOBILE HOME INSTALLATION ...
Page 53: ...Page 53 Installation and Operation Manual FW2800 ENGLISH NOTES ...