Centurion WM 2.5 User Instructions Download Page 5

required and the room thermostat

(if fitted) calls for heat, the

boiler will light and provide central heating.

If a hot water tap is opened the boiler will supply hot water.

NOTE:
(i) To provide

increased

efficiency

when providing

central

heating, the boiler control has a delay built in to prevent rapid
ON/OFF

switching

of the boiler thermostat.

Also, when the

heating

demand

is satisfied,

the pump continues

to run for

approximately

four minutes.

(ii) If the boiler fails to operate, check that the white pointer on

the pressure gauge is not below the red pointer. If necessary,
consult your installer or service engineer.

(iii) If the boiler still fails to operate, press the overheat re-set
button (fig 1) once.

TO TURN THE BOILER OFF

For short periods:

Set the Mains ON/OFF switch to OFF.

To restart, simply set the Mains ON/OFF switch to ON.

For long periods:

Set the Mains ON/OFF switch to OFF. If

frost is likely during the period of shutdown

it is necessary

to

leave the mains electricity

and gas supplies

ON. The inbuilt

boiler frost protection

device will protect the boiler from frost

damage.
To restart, refer to the lighting instructions above.

NOTE: If it is desired to turn off the power and gas supply (e.g.

for a long absence) it is necessary to drain the system.

OPERATING THE OPTIONAL HEATING TIMER (IF

FinED)

The

electronic

timer

display

(24

hr

clock)

provides

a

permanent

display of the time of day and day of the week. If

the boiler is switched off or its power supply interrupted, a built

in battery will operate the display and protect the programme
of operating times etc.

DOMESTIC HOT WATER

TEMPERATURE CONTROL

MAINS ON/OFF

DEMAND

MAINS ON

LIGHT

LIGHT

PRIMARY WATER ".

PRESSURE GAUGE

OPTIONAL

CENTRAL HEATING

TIMER

OVERHEAT RESET

sunON

CENTRAL HEATING
ON/OFF TEMPERATURE
CONTROL

The timer is supplied with a factory set default programme, but
this can be altered by the user. Refer to 'To set the electronic
timer' on page 4.
Operating

mode switch

(1 AUTO 0)

1

=

permanently

on,

this provides

a continuous

central

I

heating

'on' period, overriding

any other programme.

A (.~)

I

symbol appears in the display whenever

the operating

mode

switch is set to 1, to remind you that it is 'on'.

o

=

permanently

'off' - DHW only, no central heating.

AUTO = Timed.
Timer setting

switch

( RUN)

I

Set the switch to C9and the time of day and day of t'he week
can be set using the HR, MIN and DAY buttons as described
below.
Set the switch to

®

and the 'on' and 'off' times for the central

heating can be set as described below.
Set the switch to RUN and your preset programme will start.

57030

Summary of Contents for WM 2.5

Page 1: ...TURION 2 5 3 5 Wall Mounted Fan Assisted Gas Fired Instantaneous Combination Boiler s InstructIons Centurion WM 2 5 WM 3 5 G C No 47 13003 FOR NATURAL GAS ONLY Part No PL35984 ISSUE 2 DATE March 1997 57030 ...

Page 2: ... 1 Method of operation 1 Gas Consumer Council 2 Boiler Clearances 2 Ventilation 2 Lighting the Boiler 2 To turn off the Boiler 3 Operation of Controls 3 Central Heating Timer Operation 3 General Notes and Care of your system 5 Servicing and Maintenance 6 Cleaning 6 Spare Parts and Service 6 57030 ...

Page 3: ...flue The appliance has been designed for use on a sealed water central heating system and is suitable for use with natural gas only The appliance provides central heating at outputs between 8 8 kW 30 100 Btu h and 22 0 kW 75 000 Btu h Hot water is produced at outputs between 6 3 kW 21 600 Btu h and 27 7 kW 94 500 Btu h Incorporated within the appliance are a User adjustable controls for domestic h...

Page 4: ...become obstructed TO LIGHT THE BOilER Refer to Figure 1 IF OPTIONAL TIMER IS FITTED a Ensure that the gas and water supplies are turned on the electricity supply to the boiler is off the Mains ON OFF switch is set to OFF the timer is correctly set refer to figure 2 and the room thermostat if fitted is set at the desired setting Set the central heating OFF ON TEMPERATURE CONTROL to the desired temp...

Page 5: ... off the power and gas supply e g for a long absence it is necessary to drain the system OPERATING THE OPTIONAL HEATING TIMER IF FinED The electronic timer display 24 hr clock provides a permanent display of the time of day and day of the week If the boiler is switched off or its power supply interrupted a built in battery will operate the display and protect the programme of operating times etc D...

Page 6: ...isappears press it again and it will reappear under Sunday If the button is kept pressed in it will quickly advance through the above sequence HR button Use this button to set the hours for the time of day and the on off times Keep the button pressed in to advance the time rapidly then press release it for individual hrs MIN button Use this button to set the minutes in the same manner as the HR bu...

Page 7: ...e HR and MIN buttons to set the actual time for the end of the first heating period g Q Operations d to f can be repeated to give you up to eight heating periods in the selected group of days You do not need to use all of the switching modes Cl IMPORTANT You must use the DAY button to select the Q required day or groups of days for each on off period before setting the time for each on off period ...

Page 8: ...ng the radiators using the vent screw at the top of the radiators Only vent a radiator if the top is cool and the bottom is hot Excessive venting will reduce the system pressure so only vent when necessary and check the system pressure as mentioned above Note Your sealed system may incorporate a Top Up vessel advice on how to use it should be obtained from your Installer Domestic hot water system ...

Page 9: ...gineers In the unlikely event of a breakdown please contact Centurion on 01473 747472 or alternatively your installation or servicing company To help us provide you with a fast and efficient service please quote the boiler number and G C number This can be found on the label on the inside of the control panel door 57030 ...

Page 10: ...previous issue CENTURION GAS PRODUCTS LTD PO Box 323 Ipswich IP1 5JB Tel 01473747472 Fax 01473747479 Centurion Gas Products policy is one of continuous research and development This may necessitate alterations to this specification ...