8. STORAGE

 

 
For best results, always store your equipment in a dry environment. 

 
 

9. SHIPPING AND TRANSPORTATION 

 

The equipment can be easily carried or shipped by putting the equipment into the 
shipping boxes provided or other shipping boxes suitable for commercial transportation 
and the product dimensions and weights. 
 

 

10. THREE MONTH RENTAL PROGRAM 

 
You may not be sure if this is the type of therapy you need at home. But, you have 
probably heard a lot of positive things being said about the 

Centurion Systems 

and you 

might wonder if the therapy will work for you. Our three (3) month rental program will 
allow you to use the therapy on a trial basis. This program is long enough to enable you 
to experience the benefits of magnetic field therapy first hand, and short enough that you 
are not bound to a long-term agreement. At the end of the three-month rental period, there 
are a number of programs available to help you acquire the 

Centurion System 

on a 

lifetime basis. 

 
 

11. COMMONLY ASKED QUESTIONS 

 

Q1. 

Is it normal for a person to feel very relaxed during or after a session, especially on a  

       low frequency setting? 
 

ANS: 

Yes - The low frequency setting has an extremely relaxing effect on the body and it  

           is common to feel extremely relaxed. 

 
Q2. 

Can Magnetic Field Therapy be used in conjunction with other therapies? 

 

ANS: 

Yes - The therapy can be used by itself or in combination with other therapies. 

 
Q3. 

Will I have guaranteed results from using Magnetic Field Therapy? 

 

ANS: 

No! No therapy or drug will ever be 100% successful in treating all conditions. As  

          each person is different, the results can vary from one to another. The three-month  
          rental program allows you to find out if this therapy will benefit you with the  
          particular problems you experience. 

 

 
 
 

Summary of Contents for EZY System

Page 1: ...October 2016 Operation Manual for use as an aid in the management of musculoskeletal disorders Pulsed Magnetic Field Therapy EZY System Centurion...

Page 2: ...2 Installation Instructions 2 1 System Contents 5 2 2 System Assembly 5 2 2 1 Connection of Power and Applied Part 5 2 2 2 Positioning of the Coil 7 3 Operating Instructions 3 1 The EZY System Contro...

Page 3: ...17 6 Troubleshooting 6 1 General Operation Checkup 18 6 2 General Troubleshooting 19 7 Technical Specifications 7 1 Regulatory Compliance 20 7 2 Equipment Classifications 20 7 3 Electrical Specificat...

Page 4: ...a conductor a magnetic field will be set up in that conductor that is perpendicular to the conductor and if combined with other conductors as is found in a coil structure these fields are additive By...

Page 5: ...nt misuse of the device that may cause it to malfunction NOTES General information provided to the user to further explain or clarify the proper operation of the device APPLIED PART Applied Part is th...

Page 6: ...in your system 1 EZY System Handheld Controller 1 EZY System Lightweight Coil 1 Applied Part Cable 1 Power Cord 1 Power Adapter Assembly 1 Operating Manual 1 Test Magnet 2 2 SYSTEM ASSEMBLY The Centu...

Page 7: ...G Do not remove the ground pin from the power cord or bend it over or use an extension cord that will allow the cord not to be connected to ground Failure to maintain a proper ground while operating t...

Page 8: ...s you may find alternative positions that maximize your comfort during treatment sessions While the EZY System is lightweight and can easily be positioned as and where needed the elderly and infirm ma...

Page 9: ...ure 6 Thighs Figure 7 Thighs Figure 8 Lower Back Figure 9 Abdomen Figure 10 Shoulders You may find that some coil positions are more comfortable in a lying pose Experiment with the EZY System on a cha...

Page 10: ...ction switches that are conveniently located on the front of the unit Session time is selectable in ten minute increments ranging from 20 minutes to 60 minutes When FREQ frequency and TIME selections...

Page 11: ...2016 EZY System Manual Page 10 Figure 12 Turn Controller ON Figure 13 Select Frequency Figure 14 Switch to Time Selection Figure 15 Select Treatment Time Figure 16 Start Treatment Figure 17 Stop Trea...

Page 12: ...selected ie the higher the frequency the quicker the light will pulse 6 You may stop or pause the treatment by pushing the START STOP button at any time see Figure 17 New frequency and time settings...

Page 13: ...f cells which function electrically See Figure 18 Electric potential has a strong relationship to cellular viability Our cells have a basic or rest potential that is necessary for normal cellular meta...

Page 14: ...important setting The frequency settings of the Centurion EZY System range from 2 to 30 Hz As seen in Figure 31 normal Earth magnetic energy varies between 8 and 10 Hz In the Centurion EZY System the...

Page 15: ...ere there is still discomfort in the area of concern it is recommended that treatment remain at 2 Hz Acute conditions may subside quicker B STIMULATION After completion of the first priority stimulati...

Page 16: ...original indication a previous loss of circulation had occurred The Reactive Phase can easily be recognized by a dramatic increase in discomfort or swelling in the area If this happens there is no ne...

Page 17: ...erviced before using CAUTION Inspect all cables and applied part daily for any signs of deterioration or damage Do not use damaged cables as they may present an electrical shock hazard If damage is ob...

Page 18: ...y may arrange to have the equipment picked up by their own shipping service or pay the additional cost above normal shipping costs for overnight or the best service available When sending in equipment...

Page 19: ...ed on the time spent to evaluate the service problem All out of Warranty repairs will be warranted for 30 Days from the date of shipment to the owner END OF LIFE INSTRUCTION Centurion Systems are desi...

Page 20: ...r off push the TIME FREQ SELECT button so that the TIME light illuminates Test the availability of time selections cycling through the minutes 20 30 40 50 and 60 by pressing the UP and DOWN buttons Le...

Page 21: ...13485 2003 ISO 14971 2009 7 2 EQUIPMENT CLASSIFICATIONS Class 3 Electrical Equipment IEC 60601 Degree of protection against Electrical shock Type BF Applied Part Mode of Operation Continuous 7 3 ELEC...

Page 22: ...nd and short enough that you are not bound to a long term agreement At the end of the three month rental period there are a number of programs available to help you acquire the Centurion System on a l...

Page 23: ...nada L4W 3A4 Phone 905 238 4860 Fax 905 238 9140 Toll Free 1 800 387 8326 WORLDWIDE Toll Free 1 800 387 8326 E Mail info centurion systems com Website www centurion systems com Centurion MAGNETIC FIEL...

Reviews: