10.3. Configuration
10.4. Wiring Diagrams
10.3.1. G-WEB
10.3.2. SMS Commands
1. Complete the wiring of the unit as per Section 8 and 10.4 of this document.
2. Power up the device and verify that the device connects to the G-WEB
platform by referring to the LCD home screen.
3. Navigate your Internet browser to http://www.gweb.co.za
(or www.g-web.com.au for Australia and New Zealand) and login to your
existing profile or, alternatively, register a new profile.
4. On the My Devices page, select Add New G-SPEAK ULTRA Device and follow
the onscreen instructions to associate the device to your profile.
5. Configure the device with the desired settings using your online portal.
All features – both basic and advanced – can be easily, and remotely,
configured via the G-WEB online interface. By simply logging into G-WEB
using any Internet-enabled device, one can add and delete devices, specify
text for input and output notifications and activations, modify device
characteristics and a plethora of other features, all from the comfort of one’s
home or office. G-WEB can be accessed by navigating to http://www.gweb.
co.za (or www.g-web.com.au for Australia and New Zealand). Note that it
will be necessary to register if you have not previously done so.
The table below lists the optional basic SMS commands available on the
G-SPEAK ULTRA. All basic and advanced configurations can be done via the
G-WEB online portal.
SMS Command
Description
P.XXXX
1
.STATUS
Device Status Request to
which the
device will respond with the following
information:
• IMEI
• Supply Voltage
• Signal Strength
•
Device date & time
P.XXXX.
AB.27821234567.BU1
Add New Phone Number
Adds a new phone number to Profile 0 and
to Button1.
P.XXXX.
AB.27831234567.
BU1.2
Add Secondary Phone Number
Adds a second phone number to Profile 0
and to Button1.
P.XXXX.DB.BU1
Delete a specific access number
Delete and clear all Voice Phones assigned
to Button 1.
P.XXXX.IO
IO Status Request
This includes custom IO and state names
configured on G-WEB
1. XXXX = Device Default Password
TABLE 4
10.2. Installation
10.2.1. G-SPEAK ULTRA Mounting
10.2.2. Calling Module
Gate Station Mounting instructions
10.2.1.1. Wall-mounting
Recommendations for wall mountings
Recommendations for Goose-neck mountings
10.2.1.2. DIN Rail-mounting
FIGURE 7
FIGURE 8
FIGURE 9
FIGURE 10
FIGURE 11
FIGURE 12
FIGURE 16
FIGURE 17
FIGURE 13
FIGURE 14
FIGURE 15
FIGURE 18
Reverse the procedure under Section 10.1 to re-assemble the G-SPEAK
ULTRA.
Ensure that sealing washer is fitted and closes off the mounting hole to
prevent water ingress.
Quick Add:
To instantly associate a device to your online profile, scan the
QR code using your mobile phone and any universal QR scanner
mobile application.
Fascia
Main Unit
The Mounting Plate is used to mount the G-SPEAK ULTRA device to a wall.
Use four screws with wall anchors (not supplied) to secure Mounting Plate.
1. Position the Calling Module on wall adjacent to entrance gate or door.
2. Mount at a height that allows for comfortably speaking into the microphone.
The recommended height is 1600mm above ground level.
1. Ensure that the Calling Module does not protrude too far into the driveway.
2. The Calling Module must not be set too far back and must be easily
accessed from a vehicle.
3. The height should allow for comfortably speaking into the microphone.
Clip the G-SPEAK ULTRA main unit into the mounting plate after it has been
secured to the wall; a ‘click’ will be heard if done correctly.
Should the G-SPEAK ULTRA need to be mounted onto a DIN-rail, a DIN-rail
mounting kit is available. Enquire at Centurion Systems (Pty) Ltd for more
information.
Secure the DIN-rail clips to the back of the mounting plate using four (4)
screws.
Position the bottom of the DIN-rail clips onto the rail, and clip the top end into
position(A). A ‘click’ will be heard if it has been done correctly(B). Clip the
G-SPEAK ULTRA main unit into the Mounting plate after it has been secured to
the wall; another ‘click’ will be heard if done correctly.
To remove the unit from the DIN-rail, remove the main unit from the mounting
plate as described in Section 10.1. Insert a small flat screwdriver into the
hole(s) shown in Figure 12, and gently pry the clips from the rail.
If the cable is surface-mounted, route the cable into the unit from underneath.
Terminate the cables into the voice communication terminals by following the
wiring diagram found under Section 10.4.
Write Call Button labels, insert into lens(es) and clip lens(es) back onto chassis.
Clip the front cover back into position and secure it with the fixing screw
provided in the kit.
Carefully remove the front cover of the gate station. Insert screwdriver as
shown, unclip the Calling Module and remove it from the base.
The Mounting Panel is used to mount the calling module to a wall or
goose-neck. Use two screws with wall anchors (not supplied) to secure the
Mounting panel to a wall, or two screw to secure it to a goose-neck.
If the cable is being routed into the unit from a concealed conduit behind the
base, knock out one of the cable entry holes provided in the base and feed
through the cable. Ensure that at least 100mm of cable extends out of the wall
or goose-neck.
Run the cable through the base, hook the Calling Module into the base as
shown below and clip the Calling Module back into position.
Mounting
Plate
Mounting
Plate
Mounting
Plate
Mounting
Plate
Mounting
Screws
Main Unit
Mounting
screws
(Not Supplied)
Wall
anchors
DIN-rail
Clips
The fascia can be removed by inserting the tips of one’s fingers into the
slots (as shown in Figures 6 and 7), and pulling outward and upward. The
fascia should pop off without effort.
10.1.2. Removing the Fascia
FIGURE 6
Fascia
Slots
• I/O Status
• Firmware Version
• Relay Status
‘click’
B
A
DIN-rail
Clip
Holes for
Screwdriver
Mounting
Plate
Cable entry
behind the base
Cable
Front Cover
Calling
Module
Screw
Cable
Cable entry
below the base
Call Button
Labels
DIN Rail
DIN-rail
Clip
DIN-rail
DIN-rail
D-Series
Controller
Calling
Module
G-SPEAK
ULTRA
P1
P2
P3
P4
P5
P6
Do not mount close
to DOSS sensor
or remote receiver.
To access the terminal blocks of the G-SPEAK ULTRA, the back plate and
fascia need to be removed. Follow the instructions below to do this.
Gently pull the two clips at the back backward to release the main G-SPEAK
ULTRA unit, and lift the unit out of the mounting plate.
TABLE 3
Voltage/Firmware/Date & Time Screen
Phone Number Screen
Airtime Balance Screen
GSM Antenna Selected Screen
Gate Status Screen
SIM Screen
IMEI Screen
Gate station Voice Numbers
• Supply Voltage
• Firmware Version
• Time
• Date
Press Enter to Refresh Airtime
Balance from Network Provider.
External GSM Antenna Selected
(connect own Antenna to SMA
connector).
Press Enter to change between
Internal and External Antennas.
Internal GSM Antenna Selected
(default).
Device SIM Phone Number.
Gate Closed
Displays the device’s IMEI number
Displays the primary and secondary Voice
Numbers allocated to their respective
buttons
SIM PIN OK
Gate Opening
SIM PIN Incorrect
Gate Status Warning
Gate Open
SIM Error
10. Configurations
10.1. Removing the Mounting Plate and Fascia
10.1.1. Removing the Mounting Plate
FIGURE 5
Main Unit
Clips
Mounting Plate
Small flat
screwdriver
Back /
Mounting panel
Back /
Mounting panel
Back /
Mounting panel
Cable
Calling
Module
Screw
Anchor
Sealing
washer
Calling
Module
Slot
Mr. X
Mr. Y
GND
IO4
P4
IO1
P1
P5
IO2
P2
P6
IO3
P3
VIN NEG