Installation of electric boiler
4.0. INSTALLATION OF ELECTRIC BOILER
The El-Cm electric boiler is aimed to be hanged on the wall. For the easier setting on the wall, there is a hanging
console on its back part which is to be hanged on wall metal dowels of M10 type or even stronger. Electric boiler has to
be hanged on the height of min. 0,6 m from the floor, because of the eventual electric heater exchange. The distance
of the side wall has to be min 0,3 m, in order to easier the approach to the boiler. The electric boiler has to be
positioned on the lowest point of the whole installation. If there is a lack of space and therefore the electric boiler has to
be installed on the highest point, an airvent vessel has to be connected on its exit point with a minimum of water
content (cca. 1 lit.). This vessel has to be connected with an airvent pot. We suggest the connection to be executed by
the authorized person.
Picture 3.
- Installation of the electric boiler El-Cm on the wall
Boiler porter
(on the back
side of the
boiler)
Screw
Wall
Boiler
After putting the
electric boiler on
the porters,
fasten the
nuts
Boiler porter
(on the back
side of the
boiler)
min. 300 mm
600
205
100
735
P
1
0
64
60
min.
600
mm
3
1
2
4
0
bar
El-Cm
EN
20
Technical manual
El-Cm