background image

GB

Sizing

Sizing of the pellet stove

Fig.5: sizing of the pellet stove mod. 90

 Cliente

 Desc.

 Materiale

Peso Kg

 Data

 Disegnatore

 Trattamento

N° Dis.

Antonio F

DO LA 03

01/11

±0.005

±0.1

±0.2

-

±0.05

±

0.1

±

0.3

±

0.5

±0.1

±

0.2

±

0.5

±1

±0.15

±

0.3

±

0.8

±1.5

±0.2

±

0.5

±1.2

±2.5

±0.3

±

0.8

±2

±4

±0.5

±1.2

±3

±6

-

±2

±4

±8

 fine

 media

 grossolana

 molto grossolana

f

m

c

v

Classe di tolleranza

Scostamenti limiti per campi di dimensioni nominali secondo

UNI ISO 2768

Designa-

zione

Denominazione

da 0.5

fino 3

oltre 3

fino 6

oltre 6

fino 30

oltre 30

fino 120

oltre 120

fino 400

oltre 400

fino 1000

oltre 1000

fino 2000

oltre 2000

fino 4000

±1°

±1°

±1°30'

±3°

±0°30'

±

0°30'

±1°

±2°

±0°20'

±

0°20'

±

0°30'

±1°

±0°10'

±

0°10'

±

0°15'

±0°30'

±0°5'

±0°5'

±0°10'

±0°20'

 fine

 media

 grossolana

 molto grossolana

Scostamenti limite in funzione dei campi di lunghezza, in mm

del lato più corto dell' angolo considerato

Designa-

zione

Denominazione

fino 10

oltre10

fino 50

oltre 50

fino 120

oltre 120

fino 400

oltre 400

-

 Indice Rev.

Note di Rev.

Data Rev.

Z.F.

 Srl

• Studio e Progettazione

• Punzonatura - Piega a CNC

• Laser Piano - Laser Tubo 3D

• Lavorazioni Meccaniche

• Verniciatura e Montaggio

Tolleranze secondo

UNI ISO 2768-C

f

m

c

v

f

m

c

v

25/06/2013

Scala

Cad

Dis cliente

25/06/2013

Stufa Pellet DIANDRA 90

AMG S.P.A.

XIAN01067

 Errore: Nessun riferimento

DATA

DATA

ZF di f.lli Zorzetto G & M snc

Punzonatura Taglio laser

Laser tubia cnc

C LIE NTE
P ER SONE DI R IF.
D ISEGNO

PROGETTAZIONE 

DATI IN INGRESSO

DESCRIZIO NE DELL'ARTICOLO

O FFERTA Z.F. AL CLIENTE
O RDINE DE LCLIENTE

BO ZZA DELRC O IN FASE D' OFFERTA

FIRMA RPS

NO RME O LEGG I DI RIFERIM ENTO
DISPON IBILITA' M ATERIE PRIME

VINCOLI AZIEN. ( capac ità macc hinari)
RIFERIMENTIP ROGETTI SIMILI

T EM P O DI  A RC H IVI AZ IO NE 3 A NN I   D O  LA  29   0 7/0 3

DO LA 2 9  12/ 06

C O M U N I C A Z IO N I V A R I E

C O N S E G N A C O N C O R D A T A

N O TE

B O ZZ A   D E L C L I E N TE

C O M P O N E N TI F O R N I TI D A L C LI E N TE

S P E C IF I C H E TE C N IC H E D E L
C L I E N TE

APPUNTI

C O M U N I C A Z I O N I , M O D I F IC H E ,

O S S E R V A Z IO N I V A R I E   D E L LA   Z . F.

D O P O I D A T I D ' IN G R E S S O

F IR M A D IR E ZI O N E

V A LI D A Z IO N E :

V A L I D A ZI O N E   E S T E R N A

V A L I D A ZI O N E I N T E R N A

R IF . O R D IN E

R IF . O R D IN E

131746

2400489

450

91

5

37

5

16

0

202

33

9

935

93

5

333

131

77

250

130

49

0

402,5

402,5

266

280

 Cliente

 Desc.

 Materiale

Peso Kg

 Data

 Disegnatore

 Trattamento

N° Dis.

Antonio F

DO LA 03

01/11

±0.005

±0.1

±0.2

-

±0.05

±

0.1

±

0.3

±

0.5

±0.1

±

0.2

±

0.5

±1

±0.15

±

0.3

±

0.8

±1.5

±0.2

±

0.5

±1.2

±2.5

±0.3

±

0.8

±2

±4

±0.5

±1.2

±3

±6

-

±2

±4

±8

 fine

 media

 grossolana

 molto grossolana

f

m

c

v

Classe di tolleranza

Scostamenti limiti per campi di dimensioni nominali secondo

UNI ISO 2768

Designa-

zione

Denominazione

da 0.5

fino 3

oltre 3

fino 6

oltre 6

fino 30

oltre 30

fino 120

oltre 120

fino 400

oltre 400

fino 1000

oltre 1000

fino 2000

oltre 2000

fino 4000

±1°

±1°

±1°30'

±3°

±0°30'

±

0°30'

±1°

±2°

±0°20'

±

0°20'

±

0°30'

±1°

±0°10'

±

0°10'

±

0°15'

±0°30'

±0°5'

±0°5'

±0°10'

±0°20'

 fine

 media

 grossolana

 molto grossolana

Scostamenti limite in funzione dei campi di lunghezza, in mm

del lato più corto dell' angolo considerato

Designa-

zione

Denominazione

fino 10

oltre10

fino 50

oltre 50

fino 120

oltre 120

fino 400

oltre 400

-

 Indice Rev.

Note di Rev.

Data Rev.

Z.F.

 Srl

• Studio e Progettazione

• Punzonatura - Piega a CNC

• Laser Piano - Laser Tubo 3D

• Lavorazioni Meccaniche

• Verniciatura e Montaggio

Tolleranze secondo

UNI ISO 2768-C

f

m

c

v

f

m

c

v

25/06/2013

Scala

Cad

Dis cliente

25/06/2013

Stufa Pellet DIANDRA 60

AMG S.P.A.

XIAN01066

 Errore: Nessun riferimento

DATA

DATA

ZF di f.lli Zorzetto G & M snc

Punzonatura Taglio laser

Laser tubia cnc

C LIE NTE
P ER SONE DI R IF.
D ISEGNO

PROGETTAZIONE 

DATI IN INGRESSO

DESCRIZIO NE DELL'ARTICOLO

O FFERTA Z.F. AL CLIENTE
O RDINE DE LCLIENTE

BO ZZA DELRC O IN FASE D' OFFERTA

FIRMA RPS

NO RME O LEGG I DI RIFERIM ENTO
DISPON IBILITA' M ATERIE PRIME

VINCOLI AZIEN. ( capac ità macc hinari)
RIFERIMENTIP ROGETTI SIMILI

T EM P O DI  A RC H IVI AZ IO NE 3 A NN I   D O  LA  29   0 7/0 3

DO LA 2 9  12/ 06

C O M U N I C A Z IO N I V A R I E

C O N S E G N A C O N C O R D A T A

N O TE

B O ZZ A   D E L C L I E N TE

C O M P O N E N TI F O R N I TI D A L C LI E N TE

S P E C IF I C H E TE C N IC H E D E L
C L I E N TE

APPUNTI

C O M U N I C A Z I O N I , M O D I F IC H E ,

O S S E R V A Z IO N I V A R I E   D E L LA   Z . F.

D O P O I D A T I D ' IN G R E S S O

F IR M A D IR E ZI O N E

V A LI D A Z IO N E :

V A L I D A ZI O N E   E S T E R N A

V A L I D A ZI O N E I N T E R N A

R IF . O R D IN E

R IF . O R D IN E

131746

2400489

Summary of Contents for CentroPelet ZS10

Page 1: ...let ZS10 TUZS10ENG 4 2014 HR Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 for installation use and maintenance of pellet stove TECHNICAL INSTRUCTIONS HEATING TECHNIQUE ...

Page 2: ...ance Centre The continued use of the device in said conditions can cause fires or flashes If you do not use the auxiliary air outlet only for models with canalisation check that the fan speed is set on zero deactivated WARNING During the stove installation operation keep children out of the work area to avoid unforeseen accidents Do not block or cover in any way the body of the stove or obstruct t...

Page 3: ...intenance Failure to observe the instructions contained in the manuals Use in non conformity with the safety directives Installation in non conformity with the norms in force in the country Installation by unqualified or untrained personnel Modifications and repairs not authorized by the manufacturer Use of non original replacement parts Exceptional events Use of pellets not approved by the manufa...

Page 4: ... feeding channels or tubes for electrical system usage through the flue even if oversized It is advisable that the flue be furnished with a chamber which collects solid material and eventual condensation situated below the vertical entrance to the flue so that it is easily opened and inspected through the air tight door Whenever flues with parallel exits are used it is advisable to raise the upwin...

Page 5: ... and an environmental well being Be sure that the room where the stove is installed has sufficient aeration and if necessary install an air intake duct with a minimum recommended diameter of 50 mm to bring in air from the outside The external air intake must communicate with the stove and positioned so that it is not obstructed It must be protected with a permanent non closable grill or other suit...

Page 6: ...per campi di dimensioni nominali secondo UNI ISO 2768 Designa zione Denominazione da 0 5 fino 3 oltre 3 fino 6 oltre 6 fino 30 oltre 30 fino 120 oltre 120 fino 400 oltre 400 fino 1000 oltre 1000 fino 2000 oltre 2000 fino 4000 1 1 1 30 3 0 30 0 30 1 2 0 20 0 20 0 30 1 0 10 0 10 0 15 0 30 0 5 0 5 0 10 0 20 fine media grossolana molto grossolana Scostamenti limite in funzione dei campi di lunghezza i...

Page 7: ...ction is obligatory if the cable issued with the stove is not long enough to reach the closet socket use an extension cable along the floor Fire Safety Distance The stove must be installed respecting the following safety conditions Minimum distance from the sides and the back must be 40 cm from moderately inflammable material Easily inflammable material must not be place closer than 80 cm in front...

Page 8: ...rect and safe placement of the air intake all the measures and prescriptions Fig 7 must be respected There are distances to respect to prevent the comburant air from being subtracted from another source for example the opening of a window could cause eddies in the outside air subtracting it from the stove Fig 7 distance from walls 5 cm ...

Page 9: ...y connect the pellet stove to the flue Fill the tank with 6mm diameter pellets Open the door and check that the basket is properly inserted in its slot and that the flame trap is located in the upper part of the combustion chamber Close the door Never open the door while the pellet stove is operating Connect the stove to an outlet with the appropriate cable received with the stove Place the switch...

Page 10: ... the residual smoke Pictures are indicative and can differ from the original product Pictures are an example to understand how the product works Operations to be performed by the Authorized Assistance Centre every season before the lighting A general cleaning inside and outside A careful cleaning of the exchange tubes A careful cleaning and disincrustation of the crucible and the relative cavity C...

Page 11: ...GB Notes ...

Page 12: ...ors or error made in transcription and all figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot In any case it reserves the right to modify its products as deemed to be required and useful without any prior notification HEATING TECHNIQUE ...

Reviews: