If you encounter a problem, first try the following solutions:  

Problem  

Solution  

The sensor is vibrating  

Make sure that the sensor is completely 
closed (all four pins/screws are in place). 

 

If they are, try pressing the sensor again  
like you did when closing it.  

The sensor is not sending measurements  

Make sure the circuit has current. 

 

Make sure that the sensor arrow points  
in the direction of the load.  

Make sure the sensors are near enough  
to the bridge for the bridge to receives  
its signals.  

Check the reception LED of the bridge.  
If it is not blinking it means that it is  
not receiving signals.  

 

Support  

More support can be obtained at  

[email protected] 

 

Summary of Contents for Panoramic Power PAN-10

Page 1: ...1 Version 1 4 January 2018 Operation and maintenance manual Unit number 0000 PAN 10 and PAN 12 Sensor installation guide...

Page 2: ...tion However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the...

Page 3: ...ux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout bro...

Page 4: ...installation guide Contents Overview 5 Workflow 5 Unpacking the hardware 5 Safety precautions 6 Hardware description 6 Mapping the site 7 Installing a sensor Attaching the sensors to the circuits Reg...

Page 5: ...ic field and also use the field as a power source The sensors do not require any maintenance Data collected by the sensors is sent to a bridge which in turn transfers the information to the Panoramic...

Page 6: ...The sensor must not be installed lying or touching bus bars or any other non insulated exposed conductors Installation is possible both on external entry exit conductors before the terminal strip as w...

Page 7: ...on in Panoramic Power System Attaching the sensors to the circuits To install a sensor follow these steps 1 Open the cover of the electrical panel board 2 Make sure you have a plan that indicates the...

Page 8: ...r particles If necessary wipe it with a dry cloth Note Whenever possible avoid installing the sensor behind wires and position it at the front of the panel board 8 Place the opening of the sensor on a...

Page 9: ...ooting If the sensor vibrates after installation you can hear the vibration noise or feel it when touching the sensor it means that the sensor is not properly closed Try to press the two parts of the...

Page 10: ...rted 50 Hz EU JPE 60 Hz US JPW 50 Hz EU JPE 60 Hz US JPW Transmission frequency 434 MHz EU 902 928 MHz US 923 MHz JPE JPW 434 MHz EU 902 928 MHz US 923 MHz JPE JPW Transmission power ERP 0 dBm Max 4 d...

Page 11: ...t the sensor is completely closed all four pins screws are in place If they are try pressing the sensor again like you did when closing it The sensor is not sending measurements Make sure the circuit...