FIGURE 1
7
Using the Detector (continued)
POWER SUPPLY
•
The detector is supplied with one 9V alkaline
battery as its standard power source.
Removing & inserting the alkaline battery
•
Open the battery cover door.
•
Insert the alkaline battery into
the battery tray according to polarity.
•
Close the battery cover door.
SET UP
Mounting the staff clamp
•
Insert the staff clamp screw
into the staff clamp thread.
•
Rotate the thumb screw until
the clamp is secured in place.
OPERATION
Powering on
•
Switch the detector on by pressing the
power button. The speaker will emit a small
tone to indicate the instrument is operating.
•
The LCD screen will display the battery level
detection mode and speaker function.
Speaker function
•
Press the speaker button
to turn the speaker off / on.
Operation with a rotary laser level
•
Turn on the rotary laser level.
•
To change between coarse and fine detection
mode press the coarse / fine mode button/
•
Move the detector into
the path of the laser beam.
•
Hold the detector upright to
detect the horizontal beam (Fig.1)
•
The direction arrows or level line on the LCD
screen will indicate the position of the laser
beam. The detector will emit a constant beep
once the level position has been located.