Electrical Warning

1. Please ensure that the required voltage is being supplied at all times.
2. The unit should be plugged into a grounded and properly-sized electrical outlet with 
    appropriate over-current protection. NEVER USE AN ADAPTER PLUG!
3. The unit should have its own dedicated outlet.
4. Do not use extension cords.
5. Do not unplug your unit by pulling on the power cord. Grip the plug firmly and pull straight  
    out from the outlet.
6. Ensure the unit is not resting on or against the electrical cord.
7. If the unit is not in use for a long period of time, best to unplug the unit from the outlet.
8. To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
9. After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to 
    do so could cause damage to the compressor.
10. If the power cuts off, wait at least 5 minutes before turning the unit on to avoid damage
     to the compressor.
 

Fault   

Probable Cause 

Action 

Fuse blown or circuit breaker tripped 

Replace fuse or reset circuit breaker. 

Power cord unplugged 

Plug in power cord 

Compressor is Not Running 

Thermostat set too high 

Set thermostat to lower temperature 

Thermostat is set too high 

Set thermostat to lower temperature. 

Airflow is blocked 

Re-arrange products to allow for proper 

air flow.   Make sure there is at least four 

inches of clearance from the fan 

Low refrigerant levels 

Contact  a  service  technician  to  check 

refrigerant levels 

Cabinet  Temperature  is  too 

Warm 

Door is slightly ajar 

Make sure door is completely closed. 

Poor switch connection 

Turn off light switch and turn it back on.

 

Bulb is not connected 

Make sure the bulb is correctly inserted 

in the socket. 

Interior Light is Not Working 

Bulb has burned out 

Replace the bulb 

Condensation  is  Collecting  on 

the Cabinet and/or Floor 

Gasket is not sealing properly 

Clean,  repair,  or  replace  the  gasket  as 

necessary 

Trouble Shooting

Summary of Contents for 69K-129

Page 1: ...69K 129 69K 129 Reach In Glass door Refrigerators English November 2016 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND SAVE THESE INSTRUCTIONS...

Page 2: ......

Page 3: ...UG 69K 129 115 60 1 6 0 23 3 8 14 0 3200 12 0 518 5 15P 69K 130 115 60 1 9 0 49 1 2 28 1 5800 18 7 669 5 15P NOTICE LOSS OR SPOILAGE OF PRODUCTS IN YOUR REFRIGERATOR FREEZER IS NOT COVERED BY WARRANTY...

Page 4: ...Unit repairs will no t be subject to standard unit warranties due to improper installation procedures NOTE...

Page 5: ...m r o f r e p r e v e n e h w e c r u o s r e w o p e h t m o r f d e t c e n maintenancefunctions or cleaning therefrigerated area Do not throw items into the storage area F ailure to heed these reco...

Page 6: ...Temperature alarm...

Page 7: ...ayed and pushthe d e y a l p s i d e b l l i w e r u t a r e p m e t l a m r o n e h t d n a g n i k n i l b s t r a t s e g a s s e m t s r e h t n i a g a T E S confirm Message Cause Outputs P1 Room...

Page 8: ...BRUSHES OR SCRAPERS o For efficient operation keep the condenser surface free of dust dirt and lint o We recommend cleaning the condenser coil at least once per month o Clean the condenser with a com...

Page 9: ...Never use an acid based cleaning solution Many food products have an acidic content which can deteriorate the finish Be sure to clean the stainless steel surfaces of ALL food products NOTE...

Page 10: ......

Page 11: ...ances between the doors and between the doors and cabinet are necessarily small be careful closing doors when children are in the area NOTE We strongly recommend that any servicing be performed by a q...

Page 12: ...t at least 5 minutes before turning the unit on to avoid damage to the compressor Fault Probable Cause Action Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker Power cord unp...

Page 13: ...MODEL 69K 129 MODEL 69K 130...

Page 14: ...MODEL 69K 129...

Page 15: ...MODEL 69K 130...

Page 16: ...7750 Georgetown Road Indianapolis IN 46268 800 289 3637 Fax 800 882 0086 www CentralRestaurant com Delivering Expert Solutions with the Personal Attention You Deserve...

Reviews: