INSTALLATION                                                                                                               

Location 

Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor 
strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much 
as 1500 pounds. Reinforce the floor as necessary to provide for maximum loading. For the most efficient 
refrigeration, be sure to provide good air circulation inside and out

.

 

 
Inside cabinet 

Do not pack the units so full that air cannot circulate. The refrigerated air is discharged at the rear of the unit. 

It is important to allow for proper air flow from the rear to the front of the unit. Obstructions to this air flow can 

cause evaporator coil freeze ups and loss of temperature or overflow of water from the evaporator drain pan. 

However, bags and other items can still be located to the far rear of the cabinet. Air is brought into the 

evaporator coil with 

fans. Prevent obstruction to allow the outlet or inlet of air flow.

 

 
Outside cabinet

   

Be sure that the unit has access to ample air. Avoid hot corners and locations near stoves and ovens. 
It is recommended that the unit be installed no closer than 2" from any wall   

 
Leveling 

A level cabinet looks better and will perform better because the doors will line up with the frames properly.   
Use a level to make sure the unit is level from front to back and side to side. Units supplied with legs will 
have adjustable bullet feet to make the necessary adjustments. If the unit is supplied with casters, no 
adjustments are available. Ensure the floor where the unit is to be located is level. 

 
Stabilizing 

All models are supplied with casters for your convenience.    It is very important, however, that the cabinet 
be installed in a stable condition with the front wheels locked while in use. 
Should it become necessary to lay the unit on its side or back for any reason, allow at least 24 hours before 
start-up to allow compressor oil to flow back to place. Failure to meet this requirement can cause 
compressor failure and unit damage. 

 
 

Unit repairs will not be subject to standard unit warranties if due to improper installation 

       

procedures. 

 

Electrical connection

 

Refer to the amperage data on page 3, the serial tag, your local code or the National Electrical Code to be 
sure the unit is connected to the proper power source.     
 

 

The unit must be turned OFF and disconnected from the power source whenever 
performing service, maintenance functions or cleaning the refrigerated area. 

 

 

 

 

 

NOTE

DANGER

Summary of Contents for 69K-126

Page 1: ...69K 126 69K 127 69K 128 Chef Base Refrigerators INSTRUCTION MANUAL English November 2016 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND SAVE THESE INSTRUCTIONS ...

Page 2: ...ped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is co...

Page 3: ... 115 60 1 5 8 6 5 1 3 3200 9 5 162 5 15P 69K 127 115 60 1 5 8 8 8 1 3 3200 10 6 200 5 15P 69K 128 115 60 1 5 8 11 1 1 3 5800 12 3 232 5 15P NOTICE LOSS OR SPOILAGE OF PRODUCTS IN YOUR REFRIGERATOR FREEZER IS NOT COVERED BY WARRANTY IN ADDITION TO FOLLOWING RECOMMENDED INSTALLATION PROCEDURES PLEASE RUN THE REFRIGERATOR FREEZER 24 HOURS PRIOR TO USAGE THANK YOU ...

Page 4: ...be installed no closer than 2 from any wall Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly Use a level to make sure the unit is level from front to back and side to side Units supplied with legs will have adjustable bullet feet to make the necessary adjustments If the unit is supplied with casters no adjustments are available E...

Page 5: ...erature Defrosting Every 6 hours the unit will turn off so the evaporator coil can defrost The controller now displays the defrost symbol When the coil temperature reaches the terminal temperature or after 20 minutes of defrost the unit will turn on SOLID STATE THERMOSRAT DESCRIPTIONS 1 FRONT PANEL COMMANDS To display target set point in programming mode it selects a parameter or confirms an opera...

Page 6: ...rd will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3s the POF message will be displayed 2 5 HOW TO UNLOCK THE KEYBOARD Hold the and keys together for more than 3s till the POF message is displayed 3 ALARM SIGNALS HOW TO SEE THE ALARM AND RESET THE RECORDED ALARM 1 Hold the or key to display the alarm si...

Page 7: ...se them to become brittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and don t require the use of tools or authorized service technicians The gaskets are Dart style and can be pulled out of the grove in the door and replaced by pressing the new one back into place Do...

Page 8: ... old refrigerator may have a cooling system that uses Ozone Depleting chemicals If you are throwing away your old refrigerator make sure the refrigerant is removed for proper disposal by a qualified service technician If you intentionally release any refrigerants you can be subject to fines and imprisonment under provisions of the environmental regulations ELECTRICAL WARNING Please ensure that the...

Page 9: ...or proper air flow Make sure there is at least four inches of clearance from the fan Low refrigerant levels Contact a service technician to check refrigerant levels Cabinet Temperature is too Warm Door is slightly ajar Make sure door is completely closed Poor switch connection Turn off light switch and turn it back on Bulb is not connected Make sure the bulb is correctly inserted in the socket Int...

Page 10: ...Service and Installation Manual 8 WIRING DIAGRAM MODEL 69K 126 69K 127 10 WIRING DIAGRAM MODEL 69K 128 ...

Page 11: ...Service and Installation Manual 11 WIRING DIAGRAM MODEL 69K 126 69K 127 69K 128 ...

Page 12: ...Central Restaurant Products GLASS DOOR MERCHANDISERS INSTRUCTION MANUAL Central Restaurant Products 7750 Georgetown Road Indianapolis IN 46268 800 289 3637 800 882 0086 fax www CentralRestaurant com ...

Reviews: